Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPAZOERR (TUE) 12. 11' 01 9:26/ST. 9 : 1 1/NO. 486 1 202483 P 24

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 23 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

another analyst, to resolve discrepancies when classification (ACM vs. non- ACM) errors occur, when asbestos identification errors occur, or when R is greater than 1.0 or less than -1 0.------------------------------------------------ ----------- Obviously single-analyst laboratories will not be able to meet this requirement. Instead, they must perform intra-analyst analyses on 1 out of every 11 samples. Record; Sample, date(s) of analyses, analysts' signatures, both results, R value, reason(s) for and resolution(s) of disagreement(s). R-bar control charts must be updated monthly for each analyst monitoring both intra-and inter­ analyst precision. These charts must include all R values from at least the three previous months. 8.2.3. Standard/Reference Analysis. At least 1 out of 100 samples must be a verified quantitative standard (Section 3.14.2) that has been routinely resubmitted to determine analyst's precision and accuracy. Results should be displayed on x-bar charts to keep track of each analyst's accuracy and precision. 8.2.4. Interlaboratory QC. The laboratory must participate in round-robin testing with at least one other ELAP-certified, independent lab. Samples should be sent to these other labs at the rate of 1 sample in 200 routine samples (1 sample in 100 for single-analyst laboratories). These samples must be samples previously analyzed as QC samples. Results of these analyses must be assessed in accordance with QC-outlier criteria detailed in the lab's QA manual. At the very least, the QA manual must address misclassifications (false positives, false negatives) and misidentification of asbestos types.

CITY_21MC1OO_OO3O5O119

NYC-WTC_000319784

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319784Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →