ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 22 of 34 198.4 Wentifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

using: R = |(A-B)/((A+B)/2)| ’ where A = First result from the analyst being checked B = Second result from same analyst for same sample (Note that these intra-analyst R values are absolute values) Intra-analyst results will require additional reanalysis, possibly including another analyst, to resolve discrepancies when classification (ACM vs. non- ACM) errors occur, when asbestos identification errors occur, or when R is greater than 1.0. Record; Sample, date(s) of analyses, analysts' signatures, both results, R value, reason(s)forand resolution(s)of disagreement(s). R control charts must be updated monthly for each analyst monitoring intra-analyst precision. These charts must include all R values from at least the three previous months. 8.2.2. Inter-Analyst Analysis QC. At least 1 out of 15 samples must be reanalyzed by another analyst. R values must be calculated for each pair of re-analyses and must be compiled and statistically evaluated for each analyst, comparing his/her result to a QC result for that same sample from another analyst using: R = (A-B)/((A+B)/2) where A = Result from the analyst being checked IB = Result from other analyst for same sample Inter-analyst results will require additional reanalysis, possibly including

CITY_21MC100_003050118

NYC-WTC_000319783

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319783Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →