(TUE) 12. 11'01 9:25/ST, 9 ; 1 1ZNO. 4861 202483 P 22 FROM US EPA/OERR

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE DTEM 6MO.

Transmission Electron Microscope Method for 3/1/97 21 of 34 198.4 identifying and Quantitating Asbestos in Non- Friable Organically Bound BuIk Samples

must be routinely resubmitted for analytical quality control according to the method detailed in Section 8.1.3. QC reanalysis must include complete re- preparation of TEM grids and slides from the original sample. All QC results must be documented in a QC notebook or on appropriate analysis sheets. Procedures for resolving analytical discrepancies must be defined and details of resolved discrepancies must be recorded. Discrepancies include classification differences (ACM vs. non-ACM), identification differences (e.g., chrysotile vs. amosite) and substantial quantitation differences, as specified below. Monthly summaries must be compiled for each analyst. One of QC’s primary functions is the timely detection and correction of deficiencies in an analytical system. If QC analysis is not performed concurrent with sample load. QC may be meaningless because analytical conditions at the subsequent time will have changed in some way. Furthermore, if postponed QC uncovers a problem in the analytical system, severe problems may have resulted. Erroneous results may have been reported to a client or additional samples may have been analyzed by the flawed system, resulting in further erroneous data. Thus QC is not an optional activity to be carried out at the convenience of the laboratory or to be postponed when sample loads are heavy. ELAP-certified laboratories must perform TEM and PLM QC concurrent with sample load and must evaluate these QC results before sending written reports to clients. 8.2.1. Intra-AnalvstQC. At least 1 out of 50 samples must be reanalyzed by the same analyst. Relative difference (R) values must be calculated for each pair of re-analyses and must be compiled and statistically evaluated forthat analyst, comparing his/her QC result to his/her original result for that same sample

CITY_21MC100_003050117

NYC-WTC_000319782

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319782Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →