Identifying asbestos in non-friable bulk samples, lab guidance

Machine-extracted title · confidence 44%

Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.

NYC-WTC_000319786–000319795
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPAZOEHR (TUE) 1 2. 1 1 • 01 9;31ZST. 9 : 1 7ZH0. 4861 202484 P 4

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 27 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

(air), and 10 pm (water) structures for ensuring accurate measurements of structures. 8 4 772. TEM Camera~ Constant:—Both phosphor viewing screeruand micrograph negatives (and/or other hard-copy media) must be calibrated using thin-film gold once a week at routinely used camera lengths for accurate measurements of ED patterns. gefiord; Nominal camera length(s) vs. (a) actual camera constant (mmA) for phosphor screen and (b) camera constant (mmA) for negative. If layer-line spacings are measured on the phosphor screen during routine analysis, the on-screen diameter (mm) of a 5.3 A ED spacing or an equivalent objective measurement of 5.3 A spacing must be recorded in the calibration notebook. Note. Camera-constant calibrations must be performed in the variety of non- eucentric positions expected to be encountered during analysis for those TEMs that cannot always hold specimens at a constant distance from the objective lens, e.g., specimen holders that are riot eucentric when tilted. In such configurations where camera constants are not demonstrably reliable to within a ±5% variation, specimens must be coated with a thin film of gold to provide an internal 0.236 nm calibration standard. This gold film must be thick enough to display the 0.236-nm ring but must be sufficiently thin to minimize masking of weaker diffraction points and absorption of low-energy X rays. 8.4.7.3. Spot Diameter: The diameter of the crossover spot used during x-ray analysis must be calibrated every three months and documented by photograph annually.

CITY_21MC100_012170733

NYC-WTC_000319788

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319788Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →