NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Background study draft on asbestos in schools related to WTC, March 2003.
NYC-WTC_000318678–000318754OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
41890 Federal Register /, Vol. 52, No. 210 / Friday. October 30, 1987 / Rules and Regulations
1. Concentration in structures per must be measurable or previously average field diameter and use this square millimeter and structures per inscribed with a scale or concentric number to calculate the field area for an cubic centimeter. circles (all scales should be metric). average grid opening. Grids are to be 2. Analytical sensitivity used for the ii. Insert a diffraction grating replica randomly selected from batches up to analysis. (for example a grating containing 2.160 1.000. 3. Number of asbestos structures. lines/mmj into the specimen holder and 4. Area analyzed. ,Note.—A grid opening is considered as one place into the microscope. Orient the Held. 5. Volume of air samples (which was . replica so that the grating lines fall initially provided by client). perpendicular to the scale on the TEM ii. The mean grid opening area must 6. Average grid size opening. fluorescent screen. Ensure that the be measured for the type of specimen 7. Number of grids analyzed. goniometer stage tilt is 0 degrees. grids in use. This can be accomplished 8. Copy of the count sheet must be iii. Adjust microscope magnification on the TEM at a properly calibrated low Included with the report to lO.OOOX or 2d,000X. Measure the magnification or on an optical 9. Signature of laboratory official to distance (mm) between two widely microscope at a magnification of indicate that the laboratory met separated lines on the grating replica. approximately 400X by using an specifications of the AHERA method. .Note the number of spaces between the eyepiece fitted with a scale that has 10. Report form must contain official lines. Take care to measure between the been calibrated against a stage laboratory identification (e.g., same relative positions on the lines (e.g., micrometer. Optical microscopy utilizing letterhead). between left edges of lines). manual or automated procedures may 11. Type of asbestos. be used providing instrument calibration Note.—The more spaces included in the J. Calibration Methodology measurement, the more accurate the final can be verified. Note: Appropriate implementation of calculation. On most microscopes, however. e. Determination of Camera Constant the method requires a person the magnification is substantially constant and ED Pattern Analysis. only within the central 8-10 cm diameter i. The camera length of the TEM in ED knowledgeable in electron diffraction region of the fluorescent screen. and mineral identification by ED and operating mode must be calibrated EDXA. Those inexperienced iv. Calculate the true magnification before ED patterns on unknown samples laboratories wishing to develop (M) on the fluorescent screen: are observed. This can be achieved by capabilities may acquire necessary M = XG/Y using a carbon-coated grid on which a knowledge through analysis of where: thin film of gold has been sputtered or appropriate standards and by following X= total distance (mm) between the evaporated, A thin film of gold is detailed methods as described in designated grating lines; evaporated on the specimen TEM grid to References 8 and 10 of Unit lU.L G = calibration constant of the grating obtain zone-axis ED patterns 1. Equipment Calibration. In this replica (lines/mm): superimposed with a ring pattern from methoi calibration is required for the Y=number of grating replica spaces the polycry'stalline gold film. air-sampling equipment and the counted along X. ii. In practice, it is desirable to transmission electron microscope c. Calibration of the EDXA System. . optimize the thickness of the gold film so (TEM). Initially, the EDXA system must be that only one or two sharp rings are a. TEM Magnification. The calibrated by using two reference obtained on the superimposed ED magnification at the fluorescent screen elements to calibrate the energy scale of pattern. Thicker gold film would of the TEM must be calibrated at the the instrument When this has been normally give multiple gold rings, but it grid opening magnification (if used) and completed in accordance with the will tend to mask weaker diffraction also at the magnification used for fiber manufacturer's instructions, calibration spots from the unknown fibrous counting. This is performed with a cross in terms of the different types of particulates. Since the unknown d- grating replica. A logbook must be asbestos can proceed. The EDXA spacings of most interest in asbestos maintained, and the dates of calibration detectors vary in both solid angle of analysis are those which lie closest to depend on the past history of the detection and in window thickness. the transmitted beam, mulitiple gold particular microscope; no frequency is Therefore, at a particular accelerating rings are unnecessary on zone-axis ED specified. After any maintenance of the voltage in use on the TEM, the count patterns. An average camera constant microscope that involved adjustment of rate obtained from specific dimensions using multiple gold rings can be the power supplied to the lenses or the of fiber will vary both in absolute X-ray determined. The camera constant is one- high-voltage system or the mechanical count rate and in the relative X-ray peak half the diameter. D. of the rings times disassembly of the electron optical heights for different elements. Only a the interplanar spacing, d. of the ring column apart from filament exchange. few minerals are relevant for asbestos being measured. the magnification must be recalibrated. abatement work, and in this procedure K. Quality Control/Quality Assurance Before the TEM calibration is the calibration is specified in terms of a Procedures (Data Quality Indicators) performed, the analyst must ensure that “fingerprint” technique. The EDXA the cross grating replica is placed at the spectra must be recorded from Monitoring the environment for same distance from the objective lens as individual fibers of the relevant airborne asbestos requires the use of the specimens are. For instruments that minerals, and identifications are made sensitive sampling and analysis incorporate an eucentric tilting on the basis of semiquantitative procedures. Because the test is sensitive. specimen stage, all speciments and the comparisons with these reference it may be influenced by a variety of cross grating replica must be placed at spectra. factors. These include the supplies used the eucentric position. d. Calibration of Grid Openings. in the sampling operation, the b. Determination of the TEM i. Measure 20 grid openings on each of performance of the sampling, the magnification on the fluorescent screen. 20 random 200-mesh copper grids by preparation of the grid from the filter i. Define a field of view on the placing a grid on a glass slide and and the actual examination of this grid fluorescent screen either by markings or examining it under the PC.M. Use a in the microscope. Each of these unit physical boundaries. The field of view calibrated graticule to measure the operations must produce a product of
NYC-WTC_000318741
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similar indexed content
NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similar indexed content
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similar indexed content
NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similar indexed content
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similar indexed content