NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 06/03/09
Floor Zip Borough Block Lot Squad # Badge #
Various_________ 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212)962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 1:25 pm to 2:30 pm
I arrived at the premise at 1:25 pm. LVI schedule informed that activities include: exterior fagade removal on 7'^
floor, tear down decons and demo them on 5”’ floor, clear floor, scrape fireproofing SW side and shafts, loading
out boxes to ATC trailer on V' floor, demo pipes & ducts, box out debris in basement.
I used north side hoist to proceed to the 7” floor.
7'*’ Floor - 8 workers were observed on the floor removing metal panels and glass from the window at the
south side of the floor; on the west side of the building exterior aluminum cover removal took place; workers
wear double suits, PPA and gloves, picking up pieces of metal, placing into the boxes and spraying with
amended water. @ Gaylord boxes were sprayed and ready to be taken down to the ground floor.
Using “A” stairwell I went to the 5*' floor.
S"’ Floor - 7 workers were present on site, demolishing the decons on the south and north sides, erecting
scaffold and platforms to reach the ceilings and the wall, tearing down the plastics and demolishing decon.
Three Gaylord boxes were on the floor ready to be taken down to the ground floor.
I used north hoist to return to the ground floor, then I proceeded to the west side decon, signed the log book,
don the appropriate level of personal protective equipment to enter the regulated area on V'loor.
Two workers were present for the decon maintenance, cleaning shower chamber and organizing the clean
room.
Negative air pressure on the floor was -0.050
1“‘ Floor - 66 workers were present. Eagle scaffolding workers were erecting scaffold and platforms by column
at the east side work area - area 3; Asbestos Handlers on scaffolds and scissor lifts were scraping fireproofing,
cleaning the floor from debris using metal shovels, placing debris into the boxes; asbestos handlers on scaffold
were scraping and washing column, cutting metal fixtures from the ceiling.
On mezzanine at the area #2 near the personal decon workers on scaffolds and scissor lifts were in the
process of scraping fireproofing, washing the ceiling and beams, spraying with amended water, cleaning the
floor from debris and placing into the boxes.
Other workers were preparing and loading out boxes through the waste decon. A large amount of debris exists
on the floor. 20 Gaylord boxes were on the floor ready for load out. 40 micro trap machine were on and 5 on
stand by. Inspection was done on micro trap tents.
I observed Intensive water leakage from 2"'' floor on top of the fire extinguisher at the east side critical
barrier. I took photos, then LVI Supervisor Louis was advised; he directed workers, who moved the fire
extinguisher to the safe place and collect excessive water.
Using entrance from first floor I proceeded to the basement.
Bsmt - No activities or workers observed on the floor. 10 micro trap machines were powered on.
I went back to the V* floor.
After following the decontamination procedure I exited the work area.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhatlan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP__WORBY_CANNATA_SUBP_000131117
NYC-WTC_000181991
OCR can misread numbers and units. Confirm readings against the page image before using them.