NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 03/05/09
Floor Zip Borough Block Lot Squad # Badge #
Various 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212)962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proi. Mgr/TRC Environmental 9:20 am to 10:40 am
I arrived at the premise at 9:20 am. LVI schedule informed that activities include: scrape fireproofing, clear off
floor, temp platforms in shaft on 3'^floor, demo walls, clear off floor, scrape fireproofing, erect platforms various
locations on 2"“ floor, clear floor, cut ducts, demo walls, ceilings on 1" floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to
enter the regulated area on 2"‘‘floor. One worker was present for the decon maintenance.
I used B stairwell to proceed to the 3'“ floor.
3''“ Floor - 41 workers were present in the process of: scraping fireproofing at the areas 2 and 3, cleaning the
floor, placing debris into the boxes; workers on scissor lifts at the various locations were cutting metal fixtures
from the ceiling; sealing the B stairwell wall, plasticizing north side platform with poly. Eagle scaffolding workers
were erecting platforms across the south side shaft; others were cutting metal and placing into the boxes,
spraying with amended water, wrapping beams with poly, preparing and loading out boxes. 8 Gaylord boxes
were ready to be taken out. Inspection was done on micro trap machines and tents.
I used B stairwell to proceed to the 2"“ floor.
2"'' Floor - 58 workers were found inside the work area. Workers on 6 scaffolds were scraping fireproofing at
the area 2, spraying with amended water, cleaning the floor, re-sealing the critical barriers, floor. Workers on
mezzanine were fine cleaning beams and columns. At the south/east side of the work area workers on scissor
lifts were breaking the brick wall, spraying with water. Eagle scaffolding workers erecting the scaffolds at the
north/east side vestibule. Other workers were cutting metal using tools attached to the HEPA vacuum,
wrapping beams with poly, preparing boxes. 30 Gaylord boxes were on the floor sealed, sprayed and ready for
load out. 35 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents.
I used B stairwell to proceed to the V* floor.
1" Floor - 78 workers were on the floor. Workers on scissor lifts at the various locations were removing
insulation and cutting heating pipes; demolishing the brick walls and spraying with amended water; workers on
scissor lifts were removing hard concrete drop ceiling, removing black metal panels from the columns at the
south side of the work area, clearing shafts, placing debris into the boxes and spraying with amended water,
cutting metal at the various locations into the pieces, preparing, wrapping and loading out boxes through the
waste decon. A large amount of debris and poly wrapped beams exists on the floor. 20 Gaylord boxes were on
the floor ready for load out. Inspection was done on micro trap machines and tents.
I used B stairwell to go back to the 3’Yoor,
After following the decontamination procedure I signed the log book and used south hoist to return to the
ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial^
Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000131067
NYC-WTC_000181963
OCR can misread numbers and units. Confirm readings against the page image before using them.