Asbestos inspection report, 130 Liberty Street, Oct 2008

Machine-extracted title · confidence 95%

Inspection record documenting an asbestos inspection at 130 Liberty Street conducted on October 2, 2008.

NYC-WTC_000181909
Page image
Scanned page image, NYC-WTC_000181909
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 10/2/08 Floor Zip Borough Block Lot Squad # Badge # Various 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU0086IV1N08 yes Contractor’s Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner's Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 9:25 pm to 10:55 pm

I arrived at the premise at 9:25 pm. LVI schedule informed that activities include final air testing North vestibule on 17*" floor, clean areas as necessary for regulators inspection FIs 18-14 on 15*" & 14*" floors - South Comp Bay.

I used north hoist to go to the IS'” floor, I proceeded to the decon, followed all precautions necessary and left decon; using stairs I went to 17*" floor.

17'" Floor - No activities or workers observed. 4 micro trap machines and 3 Air monitoring pumps were powered on. After decontaminating and signing the log book I left the decon. 7 Gaylord boxes were on the floor outside the work area to be taken out. I used stairs to go to 15*" floor.

15" Floor - One worker was outside the decon preparing boxes. 8 workers on 3 scaffolds were present inside the work area, fine cleaning the ceiling, beams, spraying with amended water, cleaning the floor, placing debris into black asbestos waste bags. I observed the holes on the ceiling and floor; Handlers Supervisor was advised to direct workers seal the holes. 4 micro trap machines were powered on.

After following the decontamination procedure suit up, don respirator, signed the log book, left the decon and used north hoist to go to 11*" floor. I proceeded to the decon on 11'" floor, signed the log book and entered the work area. Manometer reading of the negative air pressure on the floor was 0.074.

11*" Floor - 27 workers were in a process of cleaning platforms and columns of area 12, spraying with amended water, cleaning the floors around the work areas and vacuuming up the water from the cleaning, preparing boxes, wrapping of debris. I observed that electrical cables were hanging on the floor. I advised Handlers Supervisor to direct workers to lift the wires up and vacuum up the excess water from the floor. 7 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and tents.

After following the decontamination procedure I signed the log book and used north hoist to go back to the ground floor.

Inspection was done on ATC trailers.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s Initial

Borough l=Manhaltan 2=Bronx 3=Brooklyn 4=Queens 5=R.ichmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code I = Violation Issued 2=No Violation Issued 3-No access 4=Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130516

NYC-WTC_000181909

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000181909Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →