JAN 28 ’00 15Ml PR AMBASSADOR CONSTR. C0212 949 9762 TO 6693640 P.05/09 J.'iM. £ J. juu i.«4ja- ....................... jKAirnn uniiibii ................. - 11.vmj V 3 ' t y

SWftNUHATDfK COHHUl ASCHHECTS 1 i I

Memorandum PrqMxKMiH ami Address: Project No: 557^A Mayor’ Office of Emeigeney Management Project Direct or/Manager; I 7Worli Trade Center Meinhardt/Aliotra i New Y« rk, New York Client: I Silvccstein Propenies, Inc. Subject: J 7®. Fl. Generator reem insulation recommendatieiis. ___________ __ _______________ L______ Tq From Dare Prepared. Walter Weems 111 / Silverstein Properties, Inc. Juan M. Mejia January 29, 2OO0 I Dunag our ^'slk-thfwgh of the generalor room, water tank room and die American Express space the foUowins oLdervaiionsMwK made. I 1 • A aund er of aii infilvration wsis observed around the intake louveis that need to he packed and caulked. ( 2- Wc sug ?cst that the blank louVers be irtsulaitd from the inside of the room with 3 ” foiledbacked :nincral wool R-19 minimum. 3- Build a second iunod Out In the storage roo.m adjacent to ihe American e.xpress space wi± foilbackcd mineral wool thertnal insuhe .n R-19 minitniiin. I 4- Add w< ather stripping to the double door entrance. (See attached catalog Out.) - 5' Rgitiov : radiator enclosure and column enclosure and seal all Openings where air is iafiltiaiing replace enclosures and paint if lequirt I. 6- FuraUl and install (2) additional electric unit heateis as p«' attached Cosenrini’s memo. Jn sedition 0 the above reconiincndatidns the following are a list of items lequesied by die port authority during tjie final inspection. 1- Install cat tracing at existing 6” diameter pipe IB 7”. Hoot generator room. I 2- Add mdal astrigal to double doors at 23“*. floor cooling lower mechanical room. 3- Add 01 s more sprinkler head at 1 floor lelevator room in front of roll down grill. I 1

If you need any inftwatiow or cocTdinalien from our office in the above matters please call.

i i CC; Glen P /memo / DCaS i Joe Al otta/SHCA ! Martii Schneider / AC I

I I I I I ! 1 W.lS57«VM«iMIJOCSlUEM(W^«.TeBl*«U! WW JO OOC

I S'Viirtke Iliydw Co/’nell Ud./Swan>e thyden Connell & Pafinc.'i UP 295 Lahyeuc Strcrt, Hew Yq.^, m,w Yd* 10012 I 212 22d9«9fi,Fax3l22l90059 I JAN 25 2000 13=47 PfiGE.02

NYC-WTC_000171513

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000171513Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Letter re: OEM estimate response, June 1998 · Box 7DCAS

NYC-WTC_000173319

Letter from Ambassador Construction responding to the Division of Citywide Administrative Services regarding project estimates.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.903

machine-extracted · confidence unavailable · Check page ↗
Construction cost estimate, 7 WTC OEM, Feb 1998 · Box 7DCAS

NYC-WTC_000170825

Ambassador Construction submits a $10.8 million cost estimate for demolition and fit-out work at the Mayor's Office of Emergency Management.

2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.900

machine-extracted · confidence unavailable · Check page ↗
Change Order #26 submission, 7 WTC, Nov 1998 · Box 7DCAS

NYC-WTC_000171821

Letter from Ambassador Construction submitting change order #26 for drywall and electrical patching work at the Mayor's Office of Emergency Management.

1 shared non-person entities · Same agency, volume and box · similarity 0.897

machine-extracted · confidence unavailable · Check page ↗
RFI and fax log records, 1995 · Box 7DCAS

NYC-WTC_000166730

Log entries recording received faxes and requests for information related to the 7 World Trade Center project in 1995.

1 shared topics · Same agency, volume and box · similarity 0.895

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →