NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/DEP Box 44/North Access Connection, AMTRAK 10th Ave. Tunnel
Document / 2 pages

DEP letter on storm water manhole design, Feb 1984

Machine-extracted title · confidence 95%

Department of Environmental Protection comments rejecting a pressure relief manhole design and requesting energy dissipation details.

NYC-WTC_000165799–000165800

Folder label: “North Access Connection, AMTRAK 10th Ave. Tunnel”

Page image
Scanned page image, NYC-WTC_000165799
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

t 7

February 21i, 1984^/^1.

Seelye Stevenson Value & Knecht, Inc. Engineers & Planners 99 Park Avenue New York, NY 10016. RE: North Access Connection 10th Avenue Tunnel Amtrak, Borough of Manhattan

Dear Sir: In reply to your submittal of contract drawings with a letter dated January 24, 1984 on the above referenced project, please be advised of the following specific comments of this department: 1. Drawing Nos. C-D2 and C-UT2 show the pressure relief manhole as type A-1 manhole. This is not acceptable as momentum of the storm water in the force main is not being broken. The details should show either the force mains, coming at a higher ■ elevation and dropping into the pressure releif manhole or pro­ vide an energy dissipating baffle wall in the manhole where the water hits before going to the outlet pipe of the man­ hole (see enclosed sketch). 2. Make minor corrections as marked in red on drawing. Nos. C--D2, C-UTl and C-UT2. 3. The computations submitted for the slab for the chamber should i be revised as under: - ti i) The slab shall be designed one way slab. ii) The loading to be used will be the greater of the two! ! a) 1.5K/Sq. Ft. plus own weight. b) H-20 loading (including impact) plus own weight.

iii)The slab should be checked for shear and bond.

iv) The slab should be checked for lifting and lifting hooks design should be submitted. v) The proposed'removable precast R.C. slab shall be set in mortar as showin in DEP standards sheet No. 18 (copy enclosed).

NYC-WTC_000165799

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165799Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP comments on sewer plans, Nov 1983 · Box DEP Box 44

NYC-WTC_000165831

Department of Environmental Protection review comments on submitted sewer plans requiring stationing, invert elevations, and manhole labeling.

3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.933

machine-extracted · confidence unavailable · Check page ↗
DEP response to 95% plan submittal, Dec 1983 · Box DEP Box 44

NYC-WTC_000165824

Department of Environmental Protection letter acknowledging receipt of 95% plans and referring comments previously sent to the consulting engineers.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.929

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.