cc: DiMartino Novotny 1 Smith Aggarwal L Vogel Oliveri Khan/Henneberger Suspense lune 11, 198A RA: Ip

Seelye Stevenson Value &. Knecht, Inc. ..Wf, Engineers and Planners 99 Park Avenue New York, NY 10016

RE: North Access Connection 10th”.- Avenue Tunnel Amtrak, Borough of Manhattan '' „ .

Dear Sir:

In reply to your submission of structural computations for the sewer chamber 1 with a letter dated May 29, 198A,.pl ease be advised of the following comments of this department:

1. The thickness of the roof slab for the proposed chamber, shall be 12" minimum. The value of fs used to compute, steel for roof slah, invert slab-and walls shall be 20 k.s.i. and not 24 k.s.i. I 2. The^ precast reinforced concrete slab can not be lifted by sewer _ maintenance people due to its present proposed size. The design' . of the slab shall be changed to provide a standard''removable ' slab with tiie cPirfiguration of the sewer chamber changed as marked in red on the plans. i

3. The invert slab should be checked for shear and bond- il ! 4, The invert slab has been again designed as a two way slab although our comment No. 3 (i) of our letter February 21, 1984 specifically pointed that all slabs shall be designed one way.

Please revise your structural computations in accordance with the above comments and submit three (3) sets of corrected computations and contract drawings for our review and approval.

Copy to: Very truly yours. Mr. Harry Kamamis, P.E., Director Mass Transit Coordination I I, NYC Dept, of Transportation 51 Chambers St., Rm. #423 FREDERICK NOVOTNY. P.E., CHIEF Div, of Sewer Regulation & i u0 New York, NY 10007 Control, Bureau of hewers

r 1 ij • ■

1

NYC-WTC_000165786

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165786Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP comments on drainage plans, Oct 1983 · Box DEP Box 44

NYC-WTC_000165844

Department of Environmental Protection review comments on 30% plan drawings requesting key plans, legends, and distance measurements.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.957

machine-extracted · confidence unavailable · Check page ↗
DEP response to 95% plan submittal, Dec 1983 · Box DEP Box 44

NYC-WTC_000165824

Department of Environmental Protection letter acknowledging receipt of 95% plans and referring comments previously sent to the consulting engineers.

3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.952

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →