NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
254 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
NYC-WTC_000146129–000146748Folder label: “EPA OIG LAW”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
World Trade Center Emergency Project Environmental, Safety, and Health Plan I Revision 0 15 October 2001
2.5 ASBESTOS
Asbestos fibers have been found in some bulk and air samples taken within and outside of the rubble piles at the WTC site. This is not unexpected given that many structures built prior to 1979 had asbestos containing materials (ACM) used in building construction (e.g., pipe/equipment insulatio~ fireproofing, floor/ceiling tiles, electrical components, coatings). Thus, the potential exists for workers to be exposed to asbestos while removing debris from the rubble piles and in conducting demolition activities in structural damaged buildings adjacent to the piles. To help reduce the potential for asbestos exposure to personnel working within the WTC site and to minimize the spread of dust (which may contain asbestos fibers) during demolition and debris removal, loading, and transport to disposal sites, the Project bas implemented a Dust Protection and Suppression Plan (see Appendix. B).
Ongoing demolition activities in structurally damaged buildings are covered under an Emergency Declaration issued for the Project, which includes an. exemption from the normal requirements involving the investigation and abatement of ACM. If, in the future, contractors working on the WTC site become involved in renovation work in damaged buildings adjacent to • the site, it is their responsibility to contact the NYCDEP's Bureau of Environmental Compliance regarding applicable rules and regulations for asbestos abatement activities.
2.5.1 On, Above, Within, or Under Rubble Piles
Until a negative exposure assessment is made, Prime Contractors/subcontractors shall assume workers located on, above, within, or under rubble piles are exposed to asbestos in excess of the Federal OSHA permissible exposure limit (PEL} of 0.1 fibers per cubic centimeter as an eight hour time weighted average (iWA), and/or Excursion Limit of 1 fiber per cc for 30 minute sample. Where a negative exposure assessment has not been made or where exposure to asbestos. is greater than the PEL or Excursion Limit, the following shall be included, as a minimum, in the Prime Contractor's/subcontractor's ES&H program:
• Designate area on, above, within, or under rubble piles as controlled areas • Engineering and work practice controls designed to control asbestos exposure • Personal air monitoring • Respiratory protection (including written respiratory protection program) • Hygiene facilities and practices • Training • Housekeeping • Medical surveillance
In the event a negative exposure assessment is made through the exposure monitoring program discussed in Section 2.4, the DDC ES&H Director shall be notified within 24 hours of such a determination. After a negative exposure assessment bas been made, whenever there is a change of equipment, process, control, personnel or a new task has been initiated that may result in an increased exposure to asbestos, the employer shall conduct additional monitoring to reevaluate asbestos exposure.
41
NYC-WTC_000146528
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
254 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
21 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093400
A license agreement document regarding exterior cleaning services for the property at 65 Liberty Street.
19 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132519
A DEP results table showing daily asbestos air monitoring data at 100 Trinity Place from October to November 2001.
29 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099112
Invoice from Fiber Control, Inc. dated November 27, 2002, for exterior cleanup services at multiple sites including 113 Nassau Street.
8 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000130799
Invoice from Benjamin Kurzban & Son Control, Inc. for roof work completed at 15 Dutch Street.
13 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113167
Invoice from Fiber Control Inc. for cleaning services on the facade of 54 Warren Street.
13 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000099818
Billing record for asphalt and gravel roof cleanup services performed at 55 Nassau Street in November 2002.
8 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104846
Fax cover sheet transmitting permit application documents for work at 102 and 104 Greenwich Street to the NYC DEP on December 3, 2001.
12 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119790
Invoice from Fiber Control Inc. for DEP environmental protection services at 14 Barclay Street.
8 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121922
Invoice dated October 2002 for environmental remediation services performed on the exterior of 118 Chambers Street.
9 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000148952
Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.
Cited alongside this record in an Ask answer
NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
NYC-WTC_000105599
Laboratory report detailing asbestos analysis results for samples from 61 Broadway collected in September 2001.
Cited alongside this record in an Ask answer