vacuum collection equipment shall be configured to maintain a ntiinimum of 3000 feet per minute air velocity in the cleaning zone.
Make -Up Air System
1. All non-porous surfaces of the outdoor air intake located on the exterior of the building shall be cleaned using manual wet-wiping and HEPA vacuuming methods as needed to remove adhered materials. Note that the air intake for the condenser compartment of the air handling unit is located adjacent to the outdoor air intake for the makeup air system and should be cleaned concurrently. 2. The section of the duct from the outdoor air intake through the blower unit shall be cleaned using HEPA vacuum methods. It may be necessary to install a service opening in order to perform this cleaning. 3. Clean blower assembly and blower housing in place by a combination of hand vacuuming, damp wiping and air washing. As required in this document, air washing shall only be performed after a vacuum collection device has been installed. 4. Seal the diffuser openings using 6-mil ethylene sheeting to be secured with duct tape. 5. The makeup air duct shall be cleaned using a pressurized air mechanical brush system in combination with a vacuum collection device. The direction of cleaning shall be from the blower assembly toward the terminal end of the duct. (It is permissible to use a mechanical brush followed by application of pressurized air in lieu of combination style equipment.) It may be necessary to install a service opening in order to perform the duct cleaning. The vacuum collection equipment shall be configured to maintain a minimum of 3000 feet per minute air velocity in the cleaning zone.
Dissembled Duct Sections on Floor
1. Transport dissembled duct sections to the enclosure constructed for cleaning of the air handling unit for wet cleaning. The dissembled duct sections should be sprayed with Simple Green or a similar environmentally safe degreaser and hand washed as needed to remove adhered materials.
11.3.2 Food Exchange Restaurant
This is a 2,324 sq ft space with 10’ high suspended acoustical ceiling on the south side and a solid gypsum drywall suspended ceiling on the north side. An older tin ceiling is present on the deck of the south side and an additional layer of gypsum is attached to the deck on the north side. Prior to the start of work, the suspended acoustical ceiling on the south side will be removed by WRS Infrastructure and Environment, Inc.
Two nearly side-by-side air handling units are located above the ceiling. These are recirculating air units with no outdoor air supply. Return air enters the ceiling plenum through passive return grilles located in the false ceiling below each unit. The air handling units draw return air fi-om the ceiling plenum through grilles in the sides of the units. The air handling units distribute supply air to supply air ducts that extend to the north and to the south of the units. The ducts are approximately 50’ long (north-south dimension). Supply air is distributed to the occupant space through supply diffusers off of the supply duct; the diffusers are flush with the false ceiling. There are supply grilles off the supply air duct that extend in a line to the north and to the south
14
NYC-WTC_000145218
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
20 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
13 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
11 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
20 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
15 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
25 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.
Cited alongside this record in an Ask answer