NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
NYC-WTC_000145027–000145344Folder label: “NO INFO”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
General Procedures for Cleaning WTC-Related Contaminants from Ventilation Systems at 110 Liberty Street, New York, New York
1.0 SCOPE
The procedures contained in this document provide guidance for cleaning WTC-related dust in two commercial ventilation systems and in a combustion air make-up riser for the residential units within the building located at 110 Liberty Street, New York, New York, and for post-cleaning verification sampling. This document includes performance requirements and post-cleaning verification sampling for cleaning WTC-related dust and debris from ventilation systems consisting of fans, housings, ducts, air control devices, grilles and other components.
2.0 PURPOSE
The purpose of this document is to provide minimum requirements for cleaning ventilation system components that were impacted by airborne dust from the WTC collapse, and to provide procedures for post-cleaning verification sampling following clean-up.
WTC-related dust is generally considered to have common, consistent, and readily observable characteristics visually and tactilely differentiating it from common dust. WTC-related dust generally contains extremely fine particles similar in consistency to talcum powder, is light-colored, contains pulverized concrete and/or gypsum wallboard, and may contain asbestos fibers. Unless otherwise indicated by sampling and analytical testing, the following components shall be assumed to be present in WTC-related dust:
• Man-made Vitreous Fibers • Crystalline Silica • Lead • Asbestos
For this project, all specified ventilation system components shall be assumed to contain WTC-related dust and shall be cleaned accordingly.
Where sampling and analysis indicate that dust and debris in ventilation systems contain only crystalline silica, man-made vitreous fibers, lead, or <1% asbestos contamination, this procedure specifies that duct systems shall be cleaned only while maintained under negative pressure using HEPA-filtered vacuum collection equipment specific to the duct cleaning industiy. All cleaning of air handling equipment shall be performed within containment structures that are maintained under negative pressure using HEPA- filtered air filtration devices.
Where sampling and analysis indicate that dust and debris within a ventilation system contains 1% or greater asbestos as determined by standard sampling and analytical techniques, the ventilation system cleaning procedure shall be designed by a New York-licensed Project Designer. The cleaning will be performed in accordance with local, state and federal regulations as specified in the Project Design.
1
NYC-WTC_000145205
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
20 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
13 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
11 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
20 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
15 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
25 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.
Cited alongside this record in an Ask answer