HVAC consulting services invoice, NYC WTC site, 2003

Machine-extracted title · confidence 95%

Invoice for HVAC consulting services provided at the World Trade Center site in 2003.

NYC-WTC_000135339–000135553
Page image
Scanned page image, NYC-WTC_000135478
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Ventilation System Identification: Page I of 2

rsovr=• cIR -s5p AtggNY STR.&S Area Served: r ssociated mechanical room: clean ENRt400SEr i Y N d r)' Y N stored chemicals/refuse Y N System Components Surface Component [NOTE: if component not present (NP), not Dust/ WTC • not present indicate in last column] found F) or Inaccessible (1) please Debris Dust • not found i Outside air intake: Present? Present? • Location: Inaccessible Accessible for inspection? Y V N (e~cplain): louvers, grates and/or screens outside air duct outside air damper(s) Air handling unit: — outside air n ing chamber — filter rack(s) — filter media — blower assembly incl. blower wheel, blower housin ,air vanes, in-line noise — blower housing acoustical lining attenuators

— pre-heat coils — heating coils — cooling coils — re-heat coils 2 — condensate drain pan — supply air plenum — supph air plenum damper(s) — vibration collars r Supply air distribution: NP — Supply air ducts Est. total In ft_ C No. locations inspected I Specify type (circle): eial &o1sRas lined e ao fibrous class board ex-du t mood , — Accessible in-line fire dampers Est. total qty—_ No. locations inspected C) — Accessible turning vanes Est. total qt5'__ ! No. locations inspected t) — In-line reheat/cooling coils Est. total qty No. locations inspected — Supply air diffusers Est. total qty No. locations inspected` Return air distribution: — Return air ducts Est. total In ft 3p No. locations inspected____ Specify type (circle):~etal~brous Ylassli ned 'eia1 ma Y fibrous flex w Return air plenum Est. total RA plenum areas_ ! No. locations inspected { Y Return air plenum damper Est, total qty— No. locations inspected Accessible in-line fire dampers Est. total qty-__ i No. locations inspected_ Accessible turning vanes Est. total qty I No. locations inspected D T Return air grilles Est, total qty 1 No. locations inspected O 2

NYC-WTC 000135478

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135478Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →