HVAC inspection report for 250 South End Ave, Jan 2003

Machine-extracted title · confidence 100%

January 30, 2003 letter from Athenica Environmental Services regarding HVAC and environmental inspections at 250 South End Avenue.

NYC-WTC_000117345–000117374

Folder label: “250 SOUTH END av 1065089, 16/7503

Page image
Scanned page image, NYC-WTC_000117367
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visual Insneetinn Fnrm Paop I of 7. Ventilation System Identification: CA L)t Location: Area Served: rxrr if /,j Lm bE Associated mechanical room: clean~✓ Y N dry~Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC • not present [NOTE: if component not present (NP), not found (NF) or inaccessible (I) please Debris Dust • not found indicate in last column] Present? Present? • inaccessible Outside air intake: Location:

Accessible for inspection? Y N (explain):

— louvers, grates and/or screens f F — outside air duct — outside air damper(s) Nit' Air handling unit: — outside air mixing chamber — filter rack(s) — filter media — blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators — blower housing acoustical lining — pre-heat coils NP — heating coils Nt — cooling coils — re-heat coils [ N — condensate drain pan - t' — supply air plenum — supply air plenum damper(s) r7 — vibration collars Supply air distribution: j1 P — Supply air ducts Est. total In ft (1 No. locations inspected_„ Specify type (circle): 'metal ;fibrous glass lined metal) masomy fibrous glass board flex-duct wood — Accessible in-line fire dampers Est. total qty No. locations inspected P — Accessible turning vanes Est total qty $ No. locations inspected_ tj — In-line reheat/cooling coils Est, total qty No. locations inspected NP -~ — Supply air diffusers Est total qty 6 No. locations inspected 2 Return air distribution: — Return air ducts Est. total In ft 2 0 No. locations inspected of Specify type (circle): kinetal'; fibrous glass lined metal masonry fibrous glass board flex~-duct wood N — Return air plenum Est. total RA plenum areas j_—__ No. locations inspected_ — Return air plenum damper Est. total .qty No. locations inspected ( I — Accessible in-line fire dampers Est total qty No. locations inspected — Accessible turning vanes Est total qty No. locations inspected ivT — Return air grilles Est total qty No. locations inspected

NYC-WTC-000117367

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000117367Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117325 · Box DEP Box 46

Single page document header identifying the subject property as 250 South End Avenue with associated block and lot numbers.

Filed in the same folder

NYC-WTC_000117326 · Box DEP Box 46

Single page document header identifying the subject property as 250 South End Avenue with associated block and lot numbers.

Filed in the same folder

Compare copies and versions →