WTC building inspection form, 320 Albany Street

Machine-extracted title · confidence 90%

Form documenting visual facade inspections and air monitoring status for a building at 320 Albany Street.

NYC-WTC_000116169–000116225

Folder label: “320 ALBANY STREET 000301, 16/7502

Page image
Scanned page image, NYC-WTC_000116200
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visnnl Tnannetinn Rnrm pane I nr 12 Ventilation System Identificazipn• S I L -- X1•1' >tG SPL,tT L9N n" Location: Area Served: ~v~"p OOi-1 — oo "tezl=l ~~$ Associated mechanical room: clean Y N dry Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC • not present [NOTE: If component not present (NP), not found (Ni) or inaccessible (I) please Debris Dust • not found indicate in last column] Present? Present? • Inaccessible Outside air intake: Location:

Accessible for inspection? Y ✓ N (explain):

— louvers, grates and/or screens ')? 1 — outside air duct — outside air damper(s) Air handling unit: — outside air mixing chamber — filter racks) — filter media — blower assembly indl. blower wheel, blower housing, air vanes, in-line noise attenuators — blower housing acoustical lining — pre-heat coils — heating coils — cooling coils — re-heat coils t i7 — condensate drain pan — supply air plenum — supply air plenum damper(s) — vibration collars Supply air distribution: - Supply air ducts Est. total In ft --. S U No. locations inspected Specify type (circle)• g, ~ous glass ma y fibrous glass board - flex-duct wood — Accessible in-line fire dampers Est. total qty— _ No. locations inspected p NF — Accessible turning vanes Est. total qty D~ No. locations inspected O 9 F — In-line reheat/cooling coils Est. total qty No. locations inspected N7 — Supply air diffusers Est. total qty No, locations inspected_ , Return aifdistribution: — Return air ducts Est. total In ft D No. locations inspected I Specify type (circle): fibrous glass lined metal masonzv fibrous glass board flex-duct wood — Return air plenum Est. total RA plenum areas_ No. locations inspected — Return air plenum damper Est. total qty No. locations inspected — Accessible in-line fire dampers Est total qty 02. No. locations inspected O F — Accessible turning vanes Est total qty _ No. locations inspected D — Return air grilles Est. total qty L No. locations inspected

NYC-WTC-000116200

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116200Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →