WTC building inspection form, 320 Albany Street

Machine-extracted title · confidence 90%

Form documenting visual facade inspections and air monitoring status for a building at 320 Albany Street.

NYC-WTC_000116169–000116225

Folder label: “320 ALBANY STREET 000301, 16/7502”

Page image
Scanned page image, NYC-WTC_000116204
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visual Inspection Form Pea 1 nf I Ventilation System Identification: HV- OF L8 7 Location: Area Served: RV- S'w +M OF !.o — 3ob All3AN IM LD8'8 Associated mechanical room: clean~Y N dry~Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC . not present [NOTE: if component not present (NP), not found (NP) or inaccessible (1) please Debris Dust . not found indicate in last column] Present? Present? a inaccessible Outside air intake: Location:

Accessible for inspection? Y N (explain):

— louvers, grates and/or screens — oiltside air duct — outside air damper(s) Air handling unit: — outside air mixing chamber — filter rack(s) — filter media — blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators — blower housing acoustical lining — pre-heat coils — heating coils — cooling coils — re-heat coils — condensate drain pan — supply air plenum — supply air plenum damper(s) 1`1 P — vibration collars Supply air distribution: — Supply air ducts Est. total In f No. locations inspected _ Specify type (circle): metal ous ass " ed metal masonry fibrous glass board ex woo — Accessible in-line fire dampers Est, total qty No. locations inspected — Accessible turning vanes Est. total qty No. locations inspected — Inline reheat/cooling coils Est. total qty No. locations inspected — Supply air diffusers Est, total qty No. locations inspected j - Return air distribution: — Return air ducts Est. total In ft . No. locations inspected I Specify type (circle) )fibrous glass lined metal maso y fibrous alass board flex-duct woo — Return air plenum Est. total RA plenum areas 1 No. locations inspected 1 — Return air plenum damper Est. total qty No. locations inspected N — Accessible in-line fire dampers Est. total qty No. locations inspected — Accessible turning vanes Est. total qty No. locations inspected — Return air grilles Est total qty No. locations inspected

NYC-WTC-000116204

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116204Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →