EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.

NYC-WTC_000134871–000135144
Page image
Scanned page image, NYC-WTC_000135078
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part III — Health & Safety Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701— Rev 1, August 11, 2005 A licensed abatement contractor must perform the removal of all friable and non-friable ACM. Airtek believes that the implementation of these recommendations will serve to best protect human health and the environment. To assure that the removal of the aforementioned ACM is properly and effectively carried out, the following recommendations are proposed by Airtek: D. Develop and implement a schedule that outlines the time frame for removal of ACM. E. Develop complete and concise specifications to effectively deal with removal of the ACM. These specifications should be developed to comply with all applicable Federal, State and Local regulations. F. Retain the service of an independent testing laboratory to monitor the air for possible asbestos contamination before, during and after the removal work. Retain all documentation and correspondence from the removal contractor, the testing laboratory and related items in a permanent record.

5.0 ASBESTOS QUANTITY SCHEDULE: Approximate asbestos quantity schedules are presented on the following table: TABLE I SUMMARY OF INSPECTION RESULTS FOR ASBESTOS 21-23 THAMES STREET PROPOSED SUSPECT ACM THAT LAB APPROXIMATE WORK MAY BE AFFECTED ACM NOTES/SPECIFIC LOCATION RESULT QUANTITY Flashing ACM 100 SF 5th Floor Roof Bulkhead Tar ACM 75 SF 5th Floor Roof Roofing Material ACM 350 SF 5th Floor Roof Flashing ACM 41 SF 1 Floor Roof Roofing Material ACM 105 SF 1 5t Floor Roof Brick Mortar ND 0 SF Entire Coping Stone Mortar ND 0 SF 5th Floor Roof Coping Stone Caulk ACM 1 SF 5th Floor Roof —15 LF total Window Caulk ACM 9 SF Masonry Openings - 210 LF total Window Glazing ND 0 LF Entire Wall Plaster (White & ND 0 SF Entire Brown Coats 2" Floor, Storefront between Indian Rest. & Eat & Run, Basement, Apartments — Aircell Pipe Insulation ACM 50 LF This is the amount that was visible to the investigator. Pipe Insulation is assumed to exist behind/in the wall cavities/chases. Ceiling Plaster (White & Brown Coats ND 0 SF Entire Sheetrock & Joint ND Compound 0 SF Entire Rubber Tile Mastic ND 0 SF Between Indian Restaurant and Eat & Run Cementitious Duct ND 0 SF Eat & Run Insulation White Block Pipe ACM 8 LF Eat & Run Insulation Tile Grout ND 0 SF Eat & Run Total Approximate Quantity of ACM 681 SF & 58 LF

NYC-WTC 000135078

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135078Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →