NYC 9/11 Public Portal Document

Summary of Method

2.1 Quartz-fiber filters and glass adsorbent cartridges are pre-cleaned with appropriate solvents and dried in a clean atmosphere.

2.2 For sampling, the quartz-fiber filter and glass cartridge containing the PUF are installed in the high-volume air sampler.

2.3 The-high-volume sampler is then immediately put into operation;-usually for 24 hours, to sample 325 to 400 m ambient air. 3

2.4 The amount of ambient air sampled is recorded at the end of the sampling session. Sample recovery involves placing the filter on top of the PUF. The glass cartridge is then wrapped with the original aluminum foil, capped with Teflon® end caps, placed back into the original shipping container, identified, and shipped to the analytical laboratory for sample processing.

2.5 Sample preparation typically is performed on a "set" of 12 samples, which consists of 9 test samples, a field blank, a method blank, and a matrix spike.

2.7 The set of sample extracts is subjected to HRGC-HRMS selected ion monitoring (SIM) analysis using a 60-m DB-5 or 60-m SP-2331 fused silica capillary column to determine the sampler efficiency, extraction efficiency,and the concentrations or the MDLs achieved for the PHDDs/PHDFs (28). Defined identification criteria and QA/QC criteria and requirements are used in evaluating the analytical data. The analytical results along with the volume of air sampled are used to calculate the concentrations of the respective tetra- through octa-isomers, the concentrations of the 2,3,7,8-chlorine or -bromine substituted isomers, or the MDLs.

8. Apparatus 8.1 High-Volume Sampler (see Figure 2). Capable of pulling ambient air through the filter/adsorbent cartridge at a flow rate of approximately 8 standard cubic feet per minute (scfm) (0.225 std m \min) to obtain a total sample volume of greater than 325 scm over a 24-hour period.

NYC-WTC 000097550

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000097550Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000097542 · Box DEP Box 33

Chronology of clean-up precautions and air sampling results for buildings at North End Avenue and 60 Vesey Street following the September 11 attacks.

Filed in the same folder

Compare copies and versions →