Indoor environmental quality survey fax, Oct 25, 2001

Machine-extracted title · confidence 100%

Fax cover sheet from Ambient Group dated October 25, 2001 regarding indoor environmental quality surveys.

NYC-WTC_000097554–000097557

Folder label: “1 NORTH END AVENUE Block: 16 Lot: 225 BIN: 1085502 4 River Terrace, 60 Vesey Street

Page image
Scanned page image, NYC-WTC_000097554
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OCT-25-01 THU 05:04 PM AMBIENT GROUP INC FAX NO. 212 768 1540 P. 02

ambient group Inc. NAIIpNAI III AIK11:AKI I NA

Sy wlsr;})m binrrr indoor environmental quakily surveys 12!! r•I.CKXR Water treatment consulting NLWP YURK, NI•W YUKK tools Asbestos & lead field services IM.: (111) 461-781-4

Regulatory compliance programs rsx: r2t_1 4G4-gJ. 7 Air, water & soil analytical laboratories WIM: WW w.AMM1.N1C..RMM.L(TA

October 25, 2001

Mr. Elliot Zuckerman Cushman & Wakefield a/a/f Mercantile Exchange One North End Avenue New York, New York 10282

Re: One North End Avenue Ambient Project # 211338

Dear Mr. Zuckermen:

The following is a summary of the indoor environmental quality survey that Ambient•Group, Inc. performed on October 23, 2001 at the above referenced location, The survey included sampling for airborne metals, carbon dioxide, carbon monoxide, temperature, relative humidity, polynuclear aromatic hydrocarbons and airborne asbestos structures by TEM_

Analysis of all indoor readings for carbon dioxide and carbon monoxide revealed that all indoor readings were below OSHA, ACGIH, ASHR.AE and other recommended industry guidelines and/or regulations.

The indoor temperature readings ranged from 67.8'F to 68,9F, The indoor relative humidity readings ranged from 60.0% to 64.3%. All indoor temperature and relative humidity readings were consistent with the conditions described in the ASHRAE 55-1992 thermal comfort standard as well as ideal indoor conditions.

Four (4) air samples were collected from various locations on floors 3, 4, 7 and 10 and analyzed by transmission electron microscopy (TEM) for asbestos structures. The results of the analysis indicated that airborne asbestos levels inside and outside the building at the time of testing were less than the analytical sensitivity of the instrument, which is well below the EPA standard of 70 structures/mm2 as well as other recommended industry guidelines and/or regulations.

nUANI:I,. LA I I Ill A(UU, It (d.1.N t WU:, NY MIAMI, I'L 71.4 2ii. -±S: Sl6 Ong-000q joi 86ow101 ;I.t %h7- 9S.1+

10/25/01 THU 17:08 [TX/RX NO 83041

NYC-WTC 000097554

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000097554Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000097542 · Box DEP Box 33

Chronology of clean-up precautions and air sampling results for buildings at North End Avenue and 60 Vesey Street following the September 11 attacks.

Filed in the same folder

Compare copies and versions →