02-15-2002 05:17om From-GQOPER SQUARE +12126346920 T-521 P.004/010 F-791

Cooper Square Realty JLC Project # 01-2104 September 25, 2001 page 2 Air Sampling Analysis and Procedure

Introduction Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period or time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an Hi~PA filter clean bench to avoid any possible contamination.

Methodology Test procedures for these samples conform to the Natio! ial Institute of Occupational Safety and Health (NIOSH) standards.

Air sampling was conducted at a level approximating the breathing zone of persons anticipatea to be present in the area during normal operations. Sampls collected should represent the area's typical airborne fiber concentration.

All samples were collected on fully f?xposed 25 millimeter, 0.8 micrometer (.im) cellulose ester membrane air sampling cassettes with conductive cowl.

Analytical Procedures A section of the filter approximating twenty-five percent of the total filter was removed and placed on a pre-cleaned microscope slide ancr then exposed to approximately 250 microliter (i.Jl) of acetone vapor. A single 3.0 - 3.5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed upon the filter. The prepared slide was then heated on «slide heater until clarity allowed analysis to be conducted.

Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method, counting rule "A."

Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-P(: Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule. Samples weie analyzed by first dissolving the filter through a chemical process (described above) and then counting the fibers with PCM at 400x magnification. Phase contrast increases the light contra it between the object and the background, thus enhancing the microscopist's sibility to see fibers. Normally, 100 microscopic fields or 100 fibers are counted, whichever occurs first.

Analytical Results The "Summary of Analytical Results" represents the results of the analysis of the samples. The PCM limit of reliable quantification is less than 0.01 fiberJcubic centimeter (f/cc) of air if final tests do not meet these requirements. the entire work site mu-it be re-cleaned and re-tested.

NYC-WTC 000121047

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121047Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →