NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 31/114 LIBERTY 2 OF 2
Document / 15 pages

114 LIBERTY 2 OF 2

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000155407–000155421
Page image
Scanned page image, NYC-WTC_000155413
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Dm» 2. Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein. Five samples for fibrous glass and one sample for silica shall be collected in each apartment.

3. Wipe samples shall be collected before and after cleaning for lead, dioxin, and PAHs.

Prior to the cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop.

After cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop; preferably at the same location as the pre-cleaning samples.

4. The required sampling and analytical procedures are specified in Table 1. Table I: Sampling and Analytical Methods Parameter Description Sampling Analytical Method Maximum Methodology Turnaround Time Lead Wipe samples HUD Appendix 13.1 EPA Method SW-846-6010B 1 day PAHs Wipe samples ASTM D6661-01 ASTM-6661-01 14 days EPA SW-846-8270C Dioxin Wipe samples ASTM 6661-01 ASTM 6661-01 14 days EPA Method SW-846-8290 Fibrous Glass Air samples NIOSH 7400 NIOSH 7400, 3 days Counting Method “B” Crystalline Air samples NIOSH 7500 NIOSH 7500 (XRD) 14 days Silica

5. The detection limit for PAHs shall be no greater than 2.5p.g/m^.

6. Samples containing concentrations of specific congeneric analytes (PCDDs and PCDFs) considered within the scope of the dioxin sampling method that are greater than ten times the upper MCLs must be analyzed by a protocol designed for such concentration levels, e.g. Method 8280. Analytical results shall be reported using a 2,3,7,8-TCDD toxicity equivalency factor (TEF). All non-detect congeners shall be reported at 50% of the analytical sensitivity, thereby yielding a recalculated TEF.

Asbestos Air Sample Collection and Analysis

1. All asbestos air sampling methodologies shall be in accordance with the applicable sections of Title 15, Chapter 1 of the Rules of the City of New York and AHERA. __

2. Asbestos clearance air samples shall be analyzed in accordance with the NIOSH 7400 Method, and analyzed by PCM followed by TEM. The laboratory shall report a PCMe value of all fibers greater than 5 microns in length. Therefore, the lab shall report PCM, TEM and PCMe values for each sample. The detection limit shall be 0.0004 f/cc.

3 of 6

NYC-WTC_000155413

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000155413Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →