NYC 9/11 Public Portal Document
APPLIED TECHNOLOGY SERVICES, INC.
240 NORTH AVENUE
NEW ROCHELLE, NEW YORK 10801
(914) 654-0080 / (914) 654-1332 (FAx)
AMBIENT AIR AND BULK SAMPLING REPORT
On November 5 througth 8, 2001 Applied Technology Services, Inc. (ATS) provided air
and bulk sampling services at 80 to 84 West Broadway and 68 to 74 Warren St, New
York, New York. ATS's services were requested by Mark Jaffe on behalf of the owner,
due to his concerns regarding tenants health and safety.
Sampling was performed by Jose Jimenez and Steve VanderWoude, certified NYS-DOL
Inspectors.
Transmission Electron Microscopy (TEM) analysis was requested to specifically rule out
asbestos related hazards. Results of the samples analyzed via TEM indicate that all
airborne asbestos fibers levels were below the Asbestos Hazard Emergency Response Act
(AHERA) Re-occupancy Level of 70 structures per square millimeter and therefore all
areas tested may be re-occupied without the use of respiratory protection against airborne
fibers at this time.
Bulk samples were taken of the dust which was present throughout areas. Results
al
l
analyzed via TEM indicate Chrysotile asbestos was present in various samples although
not in percentages high enough (greater than 1%) to be classified as Asbestos Containing
Material (ACM).
AIR SAMPLES
ADDRESS LOCATION Asbestos Content Sample #
88 W. B. 3rd Fl. Living Room Chrysotile present 29-110601-06
88 W. B. 3rd Fl. Main Bedroom Chrysotile present 29-110601-09
72 Warren St 2'/2 Fl. Living Room Chrysotile present 29-110701-25
by window
BULK SAMPLES
82 W. B. G.P. 1st Fl Over Game Unit Chrysotile present 29-110701-44
88 W. B. 5"' Fl Window Sill Chrysotile present 29-110701-33
88 W. B. 5th Fl Gray Chair By Window Chrysotile present 29-110701-34
84 W. B. 2sF1. S Kitchen Window Sill Chrysotile present 29-110601-22
84 W. B. 2s Fl. S Wood Chair Living Room Chrysotile present 29-110601-23
74 Warren St 2nd Fl. R/S Window Sill Chrysotile present 29-110601-29
74 Warren St 2nd Fl. Sofa By Window Chrysotile present 29-110601-30
A01200
NYC-WTC 000096317