“7, ‘■K IHTHNtNtlHUri-HtLKtKN lY12U3abb0b TO 5451405 P.03/05

104 Hast 25:n Sfeei New Yorlr. N'eiw York 100'0 wvw.ate-er.virs.so.T 212353,5?.e0 Pax 212.353 3306 associates INC,

VIA FACSIMILE; 212-371-1084

October 1. 2001

40 RECTOR HOLDINGS, LLC c/o TANNENBAUM HELPERN SYRACUSE SBIRSCHTRITT LLP 900 Third Avenue New York, New York 10022-4775 Attn; Mr. Scott Furman

RE: Ambient Air Sampling 40 RECTOR STREET, New York

Dear Mr, Furman; ATC Associates Inc, (ATC) is pleased to submit this summary report presenting the asbestos air sample results for the first through nineteenth floors of 40 Rector Street. Between September 20 and 28. 2001, ATC collected five ambient air samples per floor, totaling 90 samples to ascertain the presence or absence of airborne asbestos, within the subject facility. All samples collected were analyzed in accordance with the AHERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763, Subpart E, Appendix A. Acceptable ambient air samples results are those sample sets meeting the AHERA re-occupancy requirement following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<70 s/mm'). Surnma^ of Ambient Air Sample Results for 40 Rector Street Floor Analytical Result Floor Analytical Result 1 No structures detected 10 AH samples <70 s/mm’ 2 All samples <70 s/mm’ 11 All samples <70 s/mm^ 3 All samples <70 s/mm* 12 All samples <70 s/mm’ 4 All samples <70 s/mm^ 14 All samples <70 s/mm’ 5 Sample set average 23 s/mm^ 15 All samples <70 s/mm’ 6 AH samples <70 s/mm^ 16 No structures detected 7 AH samples <70 s/mm’ 17 All samples <70 s/mm^ 8 AH samples <70 s/mm^_____ _ 18 All samples <70 s/mm’ 9 AH samples <70 s/mm’ 19 All samples <70 s/mm^

Based upon the analytical results within the AHERA clearance requirement, it is ATC's opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy. If you have any questions or require additional explaination of the information presented please do not hesitate to call me at 212-353-8280 Sincerely,

—J Fred Burkhardt Senior Project Manager ATC Associates Inc.

CITY_21MC100_004879326 NYC-WTC_000232944

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000232944Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →