Air sampling results cover letter, 47 West Street, Feb 2002

Machine-extracted title · confidence 95%

Cover letter enclosing October 2001 air sampling results for the property at 47-50 and 74-80 West Street.

NYC-WTC_000110037–000110045

Folder label: “47 WEST STREET; Block: 17 Lot: 7501 BIN: 1078973 74-80 Washington St

Page image
Scanned page image, NYC-WTC_000110038
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th Street Now York, New York 10010 www.ate-enviro.com 212.353.8280 roc 212.353.8306

VIA FACSIMILE: 212-206-5680 (1 page)

October 8, 2001

Mr. Brian Becker Time Equities Management 55 Fifth Avenue, 15`" Floor New York, NY

RE: Asbestos Ambient Air Sampling Results 47 West Street and 80 Washington Street

Dear Mr. Becker ATC Associates Inc. (ATC) is pleased to submit this summary report presenting the asbestos ambient air sample results for 47 West Street and 80 Washington Street. On September 26, 2001 ATC collected a total of thirty ambient air samples from within 47 West Street followed by the collection of 11 eleven ambient air samples from within 80 Washington Street on September 28, 2001 to ascertain the presence or absence of airborne asbestos. All samples collected were analyzed in accordance with the AHERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763, Subpart E, Appendix A. Acceptable ambient air samples results are those sample sets meeting the AHERA re-occupancy regt. Zincnt following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<70 s/mm2). Summary of Ambient Air Sample Results Building 47 West Street I All samples <70 s/mmz_~ I o;; 'v,'ashinaton Street i All samples <70 simm,'

Based upon the analytical results of less than 70 asbestos structures per square millimeter (<70 s/mm2) which is within the AHERA clearance requirement, it is ATC's opinion that the ambient air samples collected throughout the two buildings meet an acceptable criterion for re- occupancy. If you have any questions or require additional explaination of the information presented please do not hesitate to call me at 212-353-8280 Sincerely,

/5 )\9;u\ Fr d Burkhardt Senior Project Manager ATC Associates Inc. ATC Associates Inc.

3141- ' x65-3'7Uk

NYC-WTC 000110038

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000110038Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →