NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\1\DATA\MAY3002\REF1.D Vial: 9 Acq On : 30 May 2002 9:56 pm Operator: Morgan Sample : gc/ms scan 5/29 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 31 11:08 2002 Quant Results File:„GCMS0520.RES *** Quant Method : C:\HPCHEM\1\METHODS\GCMS0520.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Mon May 20 15:10:30 2002 Response via : Initial Calibration DataAcq Meth : GCMS0528
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 12.07 152 603634 40.00 ug/1 -0.08 10) Naphthalene-d8 15.70 136 2430880 40.00 ug/1 -0.10 17) Acenaphthene-diO 20.99 164 1143284 40.00 ug/1 -0.10 3 0) Phenanthrene-dl0 25.43 188 1791956 40.00 ug/1 -0.11 38) Chrysene-dl2 33.48 240 1112828 40.00 ug/1 -0.13 44) Perylene-dl2 37.65 264 706729 40.00 ug/1 -0.15 System Monitoring Compounds 28) TCMX 23.13 209 202507 35.24 ug/L -0.10 Spiked Amount 40.000 Recovery 88.10% Target Compounds Qvalue 2) N-nitrosodimethylamine 5.73 74 138859 7.66 ug/1 79 3) bis(2-Chloroethyl)ether 11.47 93 283079 11.79 ug/1 92 4) 1,3-Dichlorobenzene 11.97 146 248278 12.78 ug/1 99 5) 1,4-Dichlorobenzene 12.11 146 260163 12.22 ug/1 99 6) 1,2-Dichlorobenzene 12.63 146 255865 13.88 ug/1 99 7) 2,2'-oxybis(1-Chloropropan 12.95 45 475146 8.75 ug/1 # 94 8) N-Nitrosodi-n-propylamine 13.34 70 204212 11.98 ug/1 # 85 9) Hexachioroethane 13.47 117 81622 8.98 ug/1 98 11) Nitrobenzene 13.75 77 264651 12.53 ug/1 # 86 12) 1sophorone 14.39 82 573896 13.72 ug/1 95 13) bis(2-Chloroethoxy)methane 15.08 93 345580 12.32 ug/1 98 14) 1,2,4-Trichlorobenzene 15.59 180 215755 14.21 ug/1 98 15) Naphthalene 15.75 128 846726 15.43 ug/1 # 81 16) Hexachlorobutadiene 16.30 225 74901 10.19 ug/1 95 18) Hexachlorocyclopentadiene 18.50 237 24477 5.28 ug/1 98 19) 2-Chloronaphthalene 19.25 162 447156 17.55 ug/1 96 20) Dimethylphthalate 20.35 163 531728 16.58 ug/1 100 21) 2,6-Dinitrotoluene 20.56 165 109621 16.42 ug/1 94 2 2) Acenaphthylene 20.52 152 696310 14.91 ug/1 98 2 3) Acenaphthene 21.08 153 470377 16.86 ug/1 98 24) 2,4-Dinitrotoluene 21.73 165 138865 18.97 ug/1 # 86 25) Diethylphthalate 22.48 149 548216 18.50 ug/1 100 26) 4-Chlorophenylphenylether 22.63 204 246226 16.62 ug/1 96 27) Fluorene 22.61 166 509345 18.01 ug/1 100 29) Azobenzene 23.09 77 559386 13.10 ug/L # 90 31) N-Nitrosodiphenylamine 23.02 168 193239 16.36 ug/1 # 85 32) 4-Bromophenylphenylether 24.10 248 123360 13.19 ug/1 97 33) Hexachlorobenzene 24.53 284 143758 14.32 ug/1 97 3 4) Phenanthrene 25.49 178 731524 16.93 ug/1 99 (#) = qualifier out of range (m) = manual integration REFl.D GCMS0520.M Fri May 31 11:09:50 2002 Page 1
NYC-WTC_0000 14748
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000013325
Reference analysis report for GCMS testing of sample AE12152 listing organic compounds and response values.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013787
Calibration results for GCMS analysis of volatile organic compounds including nitrosamines and chlorinated benzenes.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013712
Laboratory report documenting GCMS analysis of sample AE12278 conducted on May 30, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000014875
Calibration data table for GCMS analysis containing internal standards and surrogate compounds dated June 3, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000012665
Laboratory report listing analytical responses for target compounds in a reference standard sample used for quality control.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023563
Laboratory report showing GC/MS reference analysis for sample AE09683 with quantitative results for volatile organic compounds.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045841
Laboratory report of GC/MS analysis using reference standards to verify detection of volatile organic compounds in May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043659
Report detailing the response values for GC/MS reference standards used to verify instrument performance on May 6, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023220
Reference standard analysis for GCMS testing of sample AE08430 dated May 9, 2002, reporting quality control spike recovery values.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023666
Laboratory report showing GC/MS reference analysis for sample AE09676 with quantitative results for volatile organic compounds.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043836
Reference gas chromatography-mass spectrometry analysis with manual result entry for sample AE09681, detecting multiple organic contaminants.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000024969
Reference standard analysis report for GCMS testing of sample AE11306 conducted on May 21, 2002, verifying instrument performance.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000014729
Laboratory report documenting GCMS analysis of sample AE12574 conducted on June 7, 2002, including surrogate recovery data.
Filed in the same folder
NYC-WTC_000014730
Header page from a GCMS method document covering the period of May 29 to May 30, 2002.
Filed in the same folder
NYC-WTC_000014733
GCMS blank analysis report for sample AE12093 dated 05/31/2002 showing all measured organic compounds below minimum reporting limits (MRL) of 2.0 micrograms.
Filed in the same folder
NYC-WTC_000014742
Laboratory blank report for GCMS analysis of volatile organic compounds conducted on May 31, 2002.
Filed in the same folder
NYC-WTC_000014754
Reference standard report for GCMS analysis of volatile organic compounds conducted on May 30-31, 2002.