NYC 9/11 Public Portal Document
SECTION 02082
reoccupancy. Evidence of asbestos contamination identified during the inspection
will necessitate further cleaning as heretofore specified.
b) When the Work Area passes the Testing Laboratory’s visual reoccupancy
inspection, during abatement air sampling shall cease and the samples shall be
brought to the laboratory for analysis. The Testing Laboratory will approve
reoccupancy if the specified fiber count in the Work Area is achieved according to
the testing laboratory.
c) When the Work Area passes the reoccupancy test, all controls and seals
established shall be removed.
d) A thin coat of lockdown encapsulant shall be applied to all plastic covered surfaces
in the Work Area.
e) Final Barrier Removal
(1) Upon receipt of acceptable clearance testing results, polyethylene sheeting
and Isolation Barriers shall be removed and disposed accordingly as
asbestos-containing material.
(2) The area surrounding the abatement work place shall be cleaned of any
visible debris utilizing HEPA vacuum and wet methods.
g) The Testing Laboratory will conduct a final visual observation. Approval must be
granted prior to break down of decontamination facility and contractor
demobilization.
4.07 MAINTENANCE OF CONTAINED WORK AREA AND DECONTAMINATION ENCLOSURE
SYSTEMS
A. Ensure that barriers are installed in a manner to appropriate to the expected weather conditions
expected during the project and for its duration. Repair damaged barriers and remedy defects
immediately upon their discovery. Visually inspect barriers at the beginning and end of each
work period.
B. Visually inspect non-Work Areas and the decontamination enclosure system for water leakage.
Check the floor below, ceiling and walls, and view beneath/or around the decontamination
enclosure system, for signs of leakage. Perform the visual inspection a minimum of twice each 8-