condition exterior and interior offices and to supplement floor mounted cabinet unit ventilators in specialized classrooms such as labs, shops, and computer rooms. The horizontal ceiling mounted unit ventilators are provided with ductwork and ceiling diffusers. The floor mounted cabinet type unit ventilators are generally used to condition exterior classrooms and are not provided with ductwork or ceiling diffusers. Outside air is provided via grilles in the outside wall and supply air is provided from a top mounted grille directly on the unit ventilator.

Description of Classroom HVAC and Smoke Purge Systems The school’s classrooms are generally 690 to 730 square feet in area and are provided with two (2) floor mounted cabinet type unit ventilators that range in capacity from 1,000 to 1,250 cfm per unit. Larger shops and labs are typically provided with either three- (3) cabinet type unit ventilators or a combination of floor mounted and ceiling mounted ducted unit ventilators. The total unit ventilator supply air and minimum outside air for each classroom/lab obtained from the original Cooper Robertson & Partners Architects design drawings dated June 1989.

The minimum outside air from the classrooms (about 525 to 750 cfm) is exhausted out of the building via general exhaust fans GE-1 and GE-2, exhaust ductwork is provided from each classroom to the general exhaust duct risers. The two existing corridor units HVAC 1 and 2 provide supply air to the school’s corridors. The supply air is returned via return air duct risers to return fans serving the HVAC-1 andHVAC-2 systems. The air riser diagram for the school indicates a SI supply riser from the HVAC-1 supply unit and a RI return riser. Similarly HVAC-2 supply’s air via the S2 riser and provided with a R2 return riser. Return air to the RI and R2 riser, from each classroom, is via the corridor ceiling return plenum. There is no return air ductwork provided for these units as normally required by current School Construction Authority (SCA) guidelines. A percentage of the outside air introduced into the building from HVAC-1 and HVAC-2 and the unit ventilators are also used as transfer air for the local toilet exhaust systems. The corridor HVAC-1 and HVAC-2 and classroom HVAC systems are interfaced to a smoke purge system per SCA guidelines. The smoke purge system consists of smoke purge fans F3 (87,625 cfm), F4 (87,625 cfm) and F5 (44,300 cfm). Smoke exhaust fans F3 and F4 are connected to a common smoke/relief riser identified as (S-Rl) on the design drawings. Smoke exhaust fan F5 is connected to a common smoke/relief riser identified as (S-R2) on the design drawings. Each riser has a fire/smoke damper in the corridor ceiling plenum. In addition, each classroom is provided with a transfer grille connected to the corridor ceiling plenum to provide a means of purging each classroom on a floor by floor basis. The transfer grilles are provided with fire dampers. In the fire smoke purge mode, all supply fans are automatically shut down thus eliminating the introduction of mechanically induced outside air. The fire/smoke dampers of the smoke purge systems are coordinated by the fire department to exhaust air on an individual floor basis.

DOE00048139.DOC Appendix 1 - Page 20

CITY_21MC100_011284791

NYC-WTC_000453567

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453567Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →