NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
34 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
NYC-WTC_000278790–000278835OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
units as normally required by current School Construction Authority (SCA) guidelines. A percentage of the outside air introduced into the building from HVAC-1 and HVAC-2 and the unit ventilators are also used as transfer air for the local toilet exhaust systems.
The corridor HVAC-1 and HVAC-2 and classroom HVAC systems are interfaced to a smoke purge system per SCA guidelines. The smoke purge system consists of smoke purge fans F3 (87,625 cfm), F4 (87,625 cfm) and F5 (44,300 cffn). Smoke exhaust fans F3 and F4 are connected to a common smoke/relief riser identified as (S-R1) on the design drawings. Smoke exhaust fan F5 is connected to a common smoke/relief riser identified as (S-R2) on the design drawings.
Each riser has a fire/smoke damper in the corridor ceiling plenum. In addition, each classroom is provided with a transfer grille connected to the corridor ceiling plenum to provide a means of purging each classroom on a floor by floor basis. The transfer grilles are provided with fire dampers.
In the fire smoke purge mode, all supply fans are automatically shut down thus eliminating the introduction of mechanically induced outside air. The fire/smoke dampers of the smoke purge systems are coordinated by the fire department to exhaust air on an individual floor basis.
A1.2 Application of Unit Ventilators
Unit ventilators are a type of HVAC terminal equipment that uses a centrifugal blower, a finned-coil heating/cooling exchanger, and an air filter. The specific equipment package installed in Stuyvesant High School is a two-pipe single coil system that uses hot water from a central boiler for heating and chilled water from a central chiller for air conditioning.
Unit ventilators are very popular for rooms requiring large amounts ventilation air, such as classrooms, since system ductwork is not required, and outside air is provided directly from the outside air grille. Other advantages and system benefits inherit with this type of terminal system include:
• Lower installed costs compared to central air systems or more complex four-pipe multiple coil systems. • Conditioning and temperature control on a room by room basis and the ability to introduce 100% outside air for economy cooling cost effectively. • System controls are provided on a unitary basis providing flexibility and diversification. Each room occupant can control fan speed on a unit by unit basis and unit capacity is provided in direct response to room temperature requirements. Disadvantages of this type of terminal system include limited system filtration due to filter track width and static pressure capability of the unit’s fan system. Other disadvantages with this type of terminal system include:
A:\6_RstroflttingHV AC_R.CascoM.doc
Page A1-2
CITY_21MC1OO_O1O2742O5
NYC-WTC_000278818
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
34 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
32 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
36 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
23 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
19 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455806
Safety and health survey of a DOE office space and HVAC system following employee complaints at 52 Chambers Street.
9 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
13 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
16 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250241
Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.
17 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
22 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.940 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.940 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.936 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.935 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similar indexed content
NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
Similar indexed content
NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
Similar indexed content