lounges and general surgery use.®

For school use and based on the HVAC system limitations, appropriate filtration up to 93-95% efficiency at 1 micron can be achieved with Merv 8 pleated filters.

The recommendation for new filters is as follows:

Pre Filter: 2” Tri-DEM Odor Guard - A combination carbon activated and particulate filter

After Filter: 2" Tri-DEM Mini Pleated or 4 Ply Pleated Filter

The combination filter performance of the units will provide 93-95% removal of atmospheric dust at 1-micron particulate size in accordance with ASHRAE Standard 52- 68.

Unit Ventilators

In addition to the central air handlers each classroom is provided with unit ventilators'* that introduce outside air for ventilation. Since the students spend the majority of their time in the classroom, upgrade of the filtration of these units is desirable.

In addition to , Burns and Roe is developing a filter upgrade for the 300 Unit Ventilators installed at Stuyvesant High School.

The final consensus for the proposed upgrade is under study and will be developed after a review of air balance testing. The conversion to single speed motors of higher HP may be required to provide the static pressure necessary for the required conversion.

Project Approach

AWL Industries, acting as a JOC contractor, was authorized by the Board of Education to proceed with the construction of new air filters racks and ductwork modifications proposed by Burns and Roe.® AWL Industries, Burns and Roe, and Air Engineering are to meet to confirm filter selection and delivery.®

’ Filter Selection above MERE grade 14 requires laminar flow, no source of infiltration, and are used for specialized applications such as hospitals and surgery units. “• The school has approximately 93 unit ventilators rated at 750 and provided with a 1/8 HP motor. ’ Bums and Roe agreed to provide sizes and construction details to the contractor * The Parents Association will be advised of developments and filter selection.

MemoOS

CITY_21MC100_012173001

NYC-WTC_000276156

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276156Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →