The recommended MERV rating for schools is a MERV rating of 6 per ASHRAE 52.2 as per the NAFA Guide to Air Filtration. To provide the highest level of indoor air quality possible the filter criteria for Health Care Central Ventilation and Air Conditioning Systems^ was also used as a design criteria.

In general the minimum number of filter beds and filter beds are as follows:

• Two (2) Beds - Filter Bed #1 30% efficiency; Filter Bed #2 90% efficiency.

Where possible, due to physical space and system operating conditions, the above design criteria was meet with a combination of the 2” carbon activated pre-filter and the use of a 24”x 24”x 30” deep bag filter having the following system characteristics.

A summary of the filter upgrades is provided in Table **.

Unit Ventilators

A schematic of a unit ventilator is provided in Figure 2. These terminal systems are popular for high density occupant spaces such as classrooms since they are able to provide large amounts of outside air economically without extensive central system ductwork. Their unitary design, on a classroom by classroom basis, also permits the design engineer to provide cooling and heating on a zone by zone basis and also provides the proper use of economy cooling to offset different space heating heating/cooling loads. The space load diversity due to exposure orientation, internal heat gains , and outside air requirements based on the number of occupants and specialized local exhaust requirements such as fume hoods, computers, etc. can be properly provided by the unit ventilators. These units are also typically provided with multi-speed fan controls to provide system capacity in addition to modulated valve control.

The basic system design consist of two and four pipe systems with typically low temperature hot water (180 to 2OO’F) and chilled water (45’F) as the preferred heating/cooling media. Eow pressure steam (5 lbs) is also a common heating media and Direct Expansion (DX) air-conditioning is an alternate cooling media where central chilled water plants are not economically feasible.

NAFA Guide to Air Filtration - Third Edition, 2001 Table 10.1 See Appendix **

DOE00048139.DOC Appendix 1 - Page 15

CITY_21MC100_011284786

NYC-WTC_000453562

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453562Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →