=> Filtration after the heating/cooling coil - Tertiary Filtration Tertiary Filtration in the supply ductwork. Filtration after the heating/cooling coil -
The most important quality of an efficient filtration system is to properly treat the outside and return air before it is introduced into the conditioned space. Outside air fresh air is ideally treated to be free of all dust, gases, and contaminants that would adversely affect the building’s occupants.
Return air typically contains particulate matter that was generated within the space in addition to particulate matter that was not removed by the supply air filtration system.
The number of filtration systems was based on the practical locations based on existing system configurations and the ability of the existing HVAC systems to be modified to accommodate the increased system static due to additional filtration systems.
Outside Air Filtration
To adequately filter the school’s outside air it was decided to add additional 2” wide filter racks for all systems. Typically this was accomplished by adding new filter racks immediately before or after the existing outside air dampers. Alternate locations were provided in the HVAC systems mixed air section where inadequate space existed to add filter racks as described above.
The filter chosen for filtering the outside air was a carbon-activated filter that would effectively filter total volatile organic compounds (TVOC’s) filtration.
The characteristics of the carbon activated pre-filter is as follows:
Return Air Filtration
To provide additional filtration of supply air, the existing 2” wide filter racks on the majority of the HVAC central air handlers were utilized. Baseline air balance testing also indicated that, for a majority of the HVAC systems, it was not mechanical feasible to increase filtration beyond the static pressure drop caused by the combination of the 2” wide pre-filter and the additional 2” wide after filter.
The filter chosen for the after filter was a 4 ply pleated filter having a MERV rating of 9- 11 and an AHSRAE 52.2 efficiency of 30-40%.
The characteristics of the 4 ply after pleated after-filter is as follows:
DOE00048139.DOC Appendix 1 - Page 14
CITY_21MC100_011284785
NYC-WTC_000453561
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
16 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250241
Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.
16 shared non-person entities · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
32 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
22 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
27 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455806
Safety and health survey of a DOE office space and HVAC system following employee complaints at 52 Chambers Street.
9 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
16 shared non-person entities · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385830
protocol for ambient air and dust sampling inside PS 89 Manhattan following WTC cleanup.
16 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274908
Draft ambient air/dust sampling protocol for asbestos at Stuyvesant High School.
15 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
16 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000291428
Guidance document related to environmental health at World Trade Center site.
Similarity score 0.945 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000291428
Guidance document related to environmental health at World Trade Center site.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similar indexed content
NYC-WTC_000455806
Safety and health survey of a DOE office space and HVAC system following employee complaints at 52 Chambers Street.
Similar indexed content
NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
Similar indexed content