• Evaluation of HVAC maintenance and operation requirements to maintain the required level of “indoor air quality” after system rehabilitation.

• Evaluation of HVAC System Performance including:

HVAC systems ability to provide design cfm after system retrofit HVAC system air diffusers and system ductwork reliability and ability to provide proper air balance and design cfm to each space. Proper HVAC zoning and environmental controls

Evaluation of HVAC systems

The site equipment audits determine that the schools are provided with two basic types of HVAC equipment: • Central Air-Handler type as shown in Figure 1 • Unit Ventilator as shown in Figure 2

Of the central air-handler’s installed in the schools various system configuration types are provided, including: • Constant Volume • Variable Air Volume • Dual Duct Systems

These systems were provided with one set of filter racks and filters that were installed at location B as shown in Figure 1 to filter both return and outside air. The type of filters and their associated MERV (Minimum Efficiency Rating Value) ratings are shown in Table 1.

Selection of Filtration Systems

The filter selection was based on two major criteria:

The ability to provide particulate filtering to an indoor air quality of 40 ug/m’ • The ability to provide total volatile organic compounds (TVOC’s) filtration.

The components of a typical central air handling system are illustrated in Figure *. Proposed location of filters are as follows:

Outside air filtration before the supply fan - Primary Filtration Filtration after the supply fan and before the first heating/cooling coil - Secondary Filtration

DOE00048139.DOC Appendix 1 - Page 13

CITY_21MC100_011284784

NYC-WTC_000453560

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453560Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →