Protection from Chemical, Biological, or Radiological Attacks

should be evaluated. Filtration costs include the periodic cost isS of the filter media, the labor cost to remove and replace filters, and the fan energy cost required to overcome the pressure loss of the filters. While higher efficiency filters tend to have a higher life cycle cost than lower efficiency filters, this is not always the case. With some higher efficiency filter systems, higher acquisition and energy costs can be offset by longer fil­ ter life and a reduced labor cost for filter replacements. Also, improved filtration generally keeps heating and cooling coils cleaner and, thus, may reduce energy costs through improve ments in heat transfer efficiency. However, when high effi­ 'I?? ciency particulate air (HEPA) filters and/or activated carbon adsorbers are used, the overall costs will generally increase substantially.

3. Ducted and non-ducted return air systems. Ducted returns offer limited access points to introduce a CBR agent. The return vents can be placed in conspicuous locations, reducing the risk of an agent being secretly introduced into the return system. Non-ducted return air systems commonly use hall­ ways or spaces above dropped ceilings as a return-air path or plenum. CBR agents introduced at any location above the dropped ceiling in a ceiling plenum return system will most likely migrate back to the HVAC unit and, without highly effi cient filtration for the particular agent, redistribute to occu pied areas. Buildings should be designed to minimize mixing between air-handling zones, which can be partially accom plished by limiting shared returns. Where ducted returns are not feasible or warranted, hold down clips may be used for accessible areas of dropped ceilings that serve as the return plenum. This issue is closely related to the isolation of lobbies and mailrooms, as shared returns are a common way for con­ taminants from these areas to disperse into the rest of the

CITY_21MC100_011104389

NYC-WTC_000291453

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000291453Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000127738 · Box DEP Box 52

Health and safety plan for Phase I deconstruction at 133-135 Greenwich Street and 21-23 Thames Street dated June 8, 2005.

Similar indexed content

NYC-WTC_000279102

Building Department memo/guide related to emergency planning after 9/11.

Similar indexed content

Compare copies and versions →