Option 2:

Pre-filter: Use 4 ply Tri-Dek (Particulate only) - 78% efficiency

Add after filter; 4 ply Tri-Dek (Particulate only) - 78% efficiency

Option 3:

Pre-filter: Use 4 ply Tri-Dek (Particulate only) - 78% efficiency

Add after filter: Combination carbon activated and Particulate filtrationi

Long Term Solutions

The continued use of after filters as a long term solution may be recommended based on field measured pressure drops, and supply air cfm during the air balance testing program. This dedsion will consider the units ability to meet the summer design-cooling load with the additional filtration and an engineering assessment if additional HV.AC performance can be obtained from motor/fan modifications.

HVAC-1

This HVAC unit is a built-up unit with outside/return air filtering rack suitable for modification. With the addition of 3" latching clips the frame can be retrofitted to accommodate an after filter as well as a pre-filter.

It is suggested to modify the unit with the following filtration:

Pre-filter: Use Odor Guard a combination of Carbon Activation and Particulate filterl

Add after filter: Bag Filter 95% @ 1 micron

Higher system filtration is possible with this unit due to existing space that accommodates bag filtration. The unit also has the ability to accommodate a higher operating static impose by the extra filtration by either fan rpm changes or motor change.

LongTenrrSplutigns

The continued use of after filters as a long term solution may be recommended based on field measured pressure drops, and supply air cfm during the air balance testing program. This decision will also consider the units ability to meet the summer design-cooling load of the corridors. Additional HVAC motor/fan modifications may be required.

HVAC-2

This HVAC unit is a built-up unit with outside/return air filtering rack. The unit is suitable for modification. Considering the constricted ductwork, extra filtration could be provided with diagonal filter configuration and construction to increase surface area and limit face velocity.

MemoOS

CITY_21MC100_012172996

NYC-WTC_000276151

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276151Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →