NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
34 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
NYC-WTC_000278790–000278835OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
8.02 Selection of Filtration Systems ASHRAE Standard 52.2 prescribes a method of testing air-cleaning devices for removal efficiency by particle size and the filter resistance to airflow. The test is conducted at a specified airflow and a corresponding selected velocity usually 500 fpm.
A composite performance curve is developed based on particle size removal efficiency performance curves and an initial performance curve over a range of particle sizes. Points on the composite curves are averaged and these averages are used to determine the Minimum Efficiency Reporting Value (MERV) of the air filter under testing. The Minimum Efficiency Removal Value (MERV Rating) is then used for comparison of different filter ability to provide particulate filtering, see Table 6-1.
Burns and Roe reviewed the HVAC central air handlers at the various schools and developed and filter modifications based on available filter rack size and by selecting filters of MERV rating that would provide the required filtration with the physical limitations of the central air handlers.
Based on a field survey of existing conditions, the baseline air balancing work the majority of the air handlers systems were provided with 2” filter racks in the mixed air stream. A few of the central systems had sufficient space for the installation of bag filters. Also, due to the presence of VOC’s due to the debris removal operations and VOC’s emanating from the World Trade Center site the use of a granular activated carbon filter for removal of gaseous pollutants and odors was of paramount consideration.
The selected pre-filter was the Odor Guard III manufactured by D-Mark Air Filtration Corporation.
The filter is 2” wide and has a carbon content of 300 grams per Square foot. At 500 feet per minute face velocity the filter has an initial resistance of .75 “ w.g. The filter is a three stage filtration product with a Primary %” polyester media for removal of particulate, a secondary carbon media, and a tertiary polyurethane foam media for arresting carbon particles.
New filter racks were constructed to accommodate primary filtering of outside air with the Odor Guard III carbon activated filter.
The central air handlers were provided with two sets of filtering. The existing 2” filter racks were provided with a 4 ply internal ring panel and link filter (Tri-Dek XL) manufactured by the Tri-Dim Corporation to provide after filtering. At 1 micron this filter has a MERV efficiency of 40% and an initial resistance of .26” w.g.; ASHRAE test data was at 300 fpm. A major advantage of this filter is that it is manufactured to the exact size requirement and configuration of the air handler facilitating installation and eliminating flow bypass around the filter rack that is common with 2x2 box type filters. The filter is approximately 1.5” deep.
Several of the schools air hartdlers had sufficient room to install larger bag filters.
A:\6_RetroflttingHVAC_R.CascorM.doc
Page 20
CITY_21MC1OO_O1O274198
NYC-WTC_00027881 1
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
34 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
32 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
36 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
23 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
19 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455806
Safety and health survey of a DOE office space and HVAC system following employee complaints at 52 Chambers Street.
9 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
13 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
16 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250241
Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.
17 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
22 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.946 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.945 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similarity score 0.941 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similar indexed content
NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
Similar indexed content
NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
Similar indexed content