It is proposed to modify the unit with the following filtration:
Pre-filter: Use Odor Guard a combination of Carbon Activation and Particulate filterl
Add after filter: Mini Pleated 85-95% efficiency
Compared to Unit 1, greater system filtration is more difficult with this unit due to physical dimensional constraints. The unit may not have the ability to accommodate a higher operating static impose by the extra filtration by either fan rpm changes or motor change. As proposed, we anticipate that any loss of supply cfm for the winter operation should be tolerable and a long-term solution must be developed for the 2002-cooling season.
Long Term Solutions
The continued use of after filters as a long term solution may be recommended based on field measured pressure drops, and supply air cfm during the air balance testing program. This decision will also consider the units ability to meet the summer design-cooling load of the corridors. Additional HVAC motor/fan modifications may be required.
HVAC-6 (One Of Four Units Serving The Auditorium)
The remaining HVAC units of the building are small package units serving the auditorium, gym. cafeteria, music room and other areas of special use. Additional filtration is recommended by ductwork modification to unit's casement, it is proposed to provide pre-filtering before the existing filter section. It is proposed to modify the HVAC 6 on a trial with the following filtration:
Add Pre-filter Use Odor Guard a combination of Carbon Activation and Particulate filterl
Filter: 2" Mini Pleated 85-95% efficiency @ 1 micron
Higher system filtration is not readily possible due to physical dimensional and static pressure constraints.
Long Term Solutions
It is proposed to modify one unit on a trial basis and then develop a retrofit procedure for the remaining three units serving the auditorium. Once all four units have been retrofitted the particulate sampling program will be utilized to determine system performance and provide the feedback to proceed with the remaining HVAC units of this size and type.
The continued use of pre filters as a long term solution may be recommended based on field measured pressure drops, and supply air cfm during the air balance testing program. This decision will also consider the units ability to meet the summer design-cooling load of the corridors. Addition^ HVAC rnotor/fan modifications may be required.
Prepared ----
’ Robert Cascone, P.E., November 21, 2001
CC*. J. MemoOS
CITy_21MC100_012172997
NYC-WTC_000276152
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
48 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
33 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
36 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106411
Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
28 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144546
Internal memo directing DEP employees to preserve all records related to the World Trade Center attacks and subsequent environmental cleanup.
16 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
39 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
27 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144741
Standard administrative notice requiring the retention of original World Trade Center records as evidence for future legal actions.
34 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153468
Page containing illegible text and a document identifier for the EPA Inspector General series.
14 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
48 shared non-person entities · 1 shared topics · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138950
Draft excerpts of EPA OIG report for NYC interactions.
20 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similarity score 0.953 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363389
Update memo on air testing plans and results for Tribeca Tower residents.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
Similarity score 0.947 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000278790
New York Council report on retrofitting HVAC systems at Ground Zero for IAQ.
Similar indexed content
Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000144546
Internal memo directing DEP employees to preserve all records related to the World Trade Center attacks and subsequent environmental cleanup.
Similar indexed content
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
Similar indexed content