It is proposed to modify the unit with the following filtration:

Pre-filter: Use Odor Guard a combination of Carbon Activation and Particulate filterl

Add after filter: Mini Pleated 85-95% efficiency

Compared to Unit 1, greater system filtration is more difficult with this unit due to physical dimensional constraints. The unit may not have the ability to accommodate a higher operating static impose by the extra filtration by either fan rpm changes or motor change. As proposed, we anticipate that any loss of supply cfm for the winter operation should be tolerable and a long-term solution must be developed for the 2002-cooling season.

Long Term Solutions

The continued use of after filters as a long term solution may be recommended based on field measured pressure drops, and supply air cfm during the air balance testing program. This decision will also consider the units ability to meet the summer design-cooling load of the corridors. Additional HVAC motor/fan modifications may be required.

HVAC-6 (One Of Four Units Serving The Auditorium)

The remaining HVAC units of the building are small package units serving the auditorium, gym. cafeteria, music room and other areas of special use. Additional filtration is recommended by ductwork modification to unit's casement, it is proposed to provide pre-filtering before the existing filter section. It is proposed to modify the HVAC 6 on a trial with the following filtration:

Add Pre-filter Use Odor Guard a combination of Carbon Activation and Particulate filterl

Filter: 2" Mini Pleated 85-95% efficiency @ 1 micron

Higher system filtration is not readily possible due to physical dimensional and static pressure constraints.

Long Term Solutions

It is proposed to modify one unit on a trial basis and then develop a retrofit procedure for the remaining three units serving the auditorium. Once all four units have been retrofitted the particulate sampling program will be utilized to determine system performance and provide the feedback to proceed with the remaining HVAC units of this size and type.

The continued use of pre filters as a long term solution may be recommended based on field measured pressure drops, and supply air cfm during the air balance testing program. This decision will also consider the units ability to meet the summer design-cooling load of the corridors. Addition^ HVAC rnotor/fan modifications may be required.

Prepared ----

’ Robert Cascone, P.E., November 21, 2001

CC*. J. MemoOS

CITy_21MC100_012172997

NYC-WTC_000276152

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276152Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →