1 Mar 72
one-fourth the blast hole depth. Stemming may be
required between each explosive charge in areas where
the rock contains open seams, joints or faults. Pre
split blast holes shall be detonated prior to drilling and
blasting the adjacent rock except when conditions will not
permit this method or when it can be demonstrated to
the satisfaction of the Contracting Officer that in special
cases a millisecond delay system will produce acceptable
rock surfaces.
1-5. Seismic Monitoring Specifications, Milton Freewater Quarry.
3-03. BLASTING FOR QUARRY OPERATIONS.
a. General; All blasting operations shall be per
formed in accordance with the applicable provisions of
Corps of Engineers Manual EM 385-1-1 dated 13 March '
1958, entitled “General Safety Requirements’’ and supple
mented by North Pacific Division Supplement, dated 15 July
I960. The Contractor shall furnish to the Contracting Offi
cer prior to each blast a plan of all blast holes showing pat
tern and depth of drilling, type of explosive used, loading
pattern, and sequence of firing. This plan shall show all
holes, charges and existing quarry face relative to quarry
boundaries by dimensions and elevations in feet. The
drilling and blasting plan is for record purposes only, and
will not absolve the Contractor of his responsibility for
using proper drilling and blasting procedures. If the Con
tractor selects and operates a quarry within one mile of
any residence, building or bridge subject to vibration dam
age by blasting, the Contractor’s blasting operations shall
be suljject to the requirements of paragraphs 3-03 b. and
3-03 , below.
b. Monitoring; All blasting for quarry operations
that are within one mile of any residence, bridge, or building
shall be monitored for each blast. No separate payment will
be made for blasting or monitoring blasts in the riprap
quarry, and all costs thereof shall be incidental to and in
cluded in the applicable Item No. 7, “Riprap, Class I,’’
Item No. 8, “Riprap, Class II,’’ or Item No. 9, “Riprap,
Class III.’’ For the initial blast of the quarry, the quantity
of explosive shall be limited to an amount which will not
cause damage to buildings, bridges, or private property in
the area. When ground characteristics for any specified
B-11
CITY_21MC100_0 12669755
NYC-WTC_000435985
OCR can misread numbers and units. Confirm readings against the page image before using them.