NYC 9/11 Public Portal Document
EM lllO-Z-3800
APP B
1 Mar 72
construction practices, shall be either replaced by him with
suitable materials (earth or concrete), or bolted, or both as
directed, at no cost to the Government.
1-4. Blasting Specifications for Roadcuts (in Basalt), Foster Regulating
Reservoir.
3-04. EXPLOSIVES. - General. - In addition to full
compliance with Section XXII, Blasting, of General Safety
Requirements, EM 385-1-1, dated 13 March 1958. The
Contractor shall submit to the Contracting Officer, for ap
proval, drawings showing the location, access thereto and
type of construction of the proposed storage magazine for
explosives, cap house and “make up shack.’’ The explo
sives storage magazine and other facilities may be located
on Government lands if satisfactory locations can be found
and are approved by the Contracting Officer; or the Con
tractor, at his option, through private negotiations, may
locate explosive magazines outside Government lands. The
Contractor shall provide and maintain access to the explo
sive storage areas at his own expense. In the use of explo
sives, the Contractor shall exercise the utmost care not to
endanger life or property. The Contractor shall use
methods and programs which will prevent damage to adjacent
landscape features and which will minimize scattering of
rock, stumps or other debris outside the finished roadway
slopes. The Contractor will be responsible for any and all
damage and/or injury resulting from the use of explosives.
J
b. Blasting. -
(1) The drilling and blasting methods and program
shall be those necessary to accomplish the excavation shown
on the contract drawings in accordance with the procedures
specified herein. Explosives shall not be used as a primary
means of transporting material outside the excavated prism.
(2) Prior to drilling for each blast, unless excepted
by the Contracting Officer, the Contractor shall submit on
an approved form a plan showing the location, size, spacing
and depth of holes, blast hole loading, sequence and pattern
of delays and special methods. Acceptance by the Con
tracting Officer of the blasting data will not relieve the
Contractor of his responsibility to produce safe and satis
factory results as set forth by these specifications.
B-9
CITY_21MC100_0 12669753
NYC-WTC_000435983
OCR can misread numbers and units. Confirm readings against the page image before using them.