NYC 9/11 Public Portal Document
EM 1110-2-3800
APP B
1 Mar 72
depths that Contractor demonstrates that tolerances can be
maintained. Presplit surfaces shall be developed to at least
three feet below the floor of a bench before the bench is
blasted, except that the bottom bench shall be pre split to
grade. General method of presplitting consists of drilling a
line of holes spaced 24 inches (48 inches for “Spillway -
Powerhouse Excavation - Rock”) apart in the prescribed
plane, loading all of these holes with an optimum amount of
Trimtex or approved equal explosive, and detonating with
Primacord or an approved equal detonating fuse. Results
will be judged by the condition of the finished surface on
which shall remain at least 70% of the length of casts for
each of the presplit drill holes. No presplitting shall be done
in the structure area until it has been demonstrated elsewhere
that the techniques proposed obtain the specified results.
Outside the structure area presplit lines shall be limited to
100 feet in length for each of the various slopes until it has
been demonstrated that the technique produces the specified
results.
B2-11. Excavation - Structure Area, a. Sequence of Exca
vation. Excavation shall be carried out in lifts as indicated
on the drawings, and shall proceed in an upstream direction.
A blasted “V” notch or stress relief slot as shown on the
drawings shall be completed for each lift before drilling for
primary blasting is done. Once a lift is started, it shall be
carried to its final surface over its entire area before
starting the next lift. Since the preservation of horizontal
and vertical corners is critical, the presplitting of the pro
tective bench shall be coordinated with the preset bolting as
shown on the drawings and specified in Division B, section
ROCK BOLTS, ANCHOR BARS, AND DRAPED FENCING.
The 20-foot wide protective bench shall be shot after the
muck from the adjacent primary blast has been removed.
Rock bolting (other than preset bolts) as specified, and indi
cated on the drawings shall be completed within 24 hours
after the protective bench is blasted.
b- Overexcavation and Backfill. Over excavation
because of a weakness inherent in the natural undisturbed
structure of the bedrock shall be performed as directed,
and the theoretical lines and grades will be adjusted ac
cordingly. Material outside the excavation limits which
are disturbed due to the fault or negligence of the Contractor
or due to his failure to exercise sound engineering or