NYC 9/11 Public Portal Document
EM 1110-2-3800
APP B
1 Mar 72
size of production shall be limited to 20,000 cu. yds. per
shot. All muck in front of any face being shot including the
structure area shall have been removed before the round is
fired. The use of millisecond delays is not initially re
stricted; however, should proper fragmentation not be ob
tained, or if overfragmentation produces excessive fines or
incipient fractures in the rock to be used for “Rock Zone 2”
and “Rock Zone 3,” the Contracting Officer reserves the
right to prohibit the use of millisecond delays and to require
the use of regular delays. Drilling equipment must be capa
ble of efficiently drilling blast holes from 2 inches to 5 inches
in diameter. The manner in which the rock breaks as excava
tion progresses will be observed and if the specified results
are not obtained, the Contractor will be required to revise
his operation as necessary. The blasting operation shall
not be revised without the prior approval of the Contracting
Officer. The Contractor shall keep records of each blasting
shot (round) including the following information: date, station
and range, lift, number of holes, hole size, consecutive
shot number, spacing, and depth; kind of explosive, quantity
and method of loading and firing; delays; fragmentation
range, and percent of grizzly fines. A copy of the records
shall be furnished the Contracting Officer after each round.
b. Structures. In the structure area blasting of the
20-foot wide protective bench and the lift immediately above
the bearing surface as shown on the drawings, shall be ac
complished using blast holes (inclined with the bottom
pointing 20° to 30° from the vertical in a downstream direc
tion). No holes shall be closer than four feet to adjacent
“Special Surfaces.’’ A slow velocity powder in the range of
5,500 feet per second shall be used in the angle holes.
Bolting of “Special Surfaces’* and anchoring is specified in
Division B, section ROCK BOLTS, ANCHOR BARS, AND
DRAPED FENCING.
c. Pre splitting. All rock surfaces 1 on 1.25 or
steeper and the 1 on 1.5 spillway apron slope shall be pre
split. All rock surface slopes 1 on 3/4 or steeper shall be
presplit prior to the time that horizontally adjacent material
within 50 feet is drilled for blasting. Spillway apron shall
be presplit lift by lift whenever the distance measured at
the bottom of the lift is approximately 50 feet horizontal
distance from the final surface. Depth of presplitting shall
be limited to 33 feet on “Special Surfaces” elsewhere to
B-7
CITY_21MC100_0 12669751
NYC-WTC_000435981
OCR can misread numbers and units. Confirm readings against the page image before using them.