NYC 9/11 Public Portal Document
Asbestos Abatement
integrity.
2. Control entry and exit into the work enclosure.
3. Ensure that employees are adequately trained in the use of
engineering controls, proper work practices, proper personal
protective equipment and in decontamination procedures.
4. Insure that employees use proper engineering controls, proper work
practices, proper personal protective equipment and proper
decontamination procedures.
5. Competent person shall check for rips and tears in work suits, and
ensure that they are mended immediately or replaced.
E. Ah’ monitoring responsibilities, as defined in OSHA regulation 1926.58, shall be
performed by a representative of the testing laboratory retained by the Contractor.
F. Contractor shall submit to the City all credentials of the designated competent
person and industrial hygiene laboratory representative for approval.
G. Air monitoring and inspection shah be conducted by the Contractor's competent
person.
H. Continuous (daily or per shift) monitoring and inspection will include Work Area
samples, personnel samples from the breathing zone of a worker to accurately
determine the employees' 8-hour TWA (unless Type C respirators are used) and
decontamination unit clean room samples.
/. Work Area samples and employee personnel samples shall be taken using
pumps whose flow rates can be determined to an accuracy of +5-percent, at a
minimum of two liters per minute. This must be demonstrated at the job site.
J. Sampling and analysis methods shall be per NIOSH 7400A.
K. Test Reports:
1. Promptly process and distribute one copy of the test results, to the
Commissioner.
2. Prompt reports are necessary so that if required, modifications to
work methods and/or practices may be implemented as soon as
possible.
3. Contractor shall by facsimile, and notify the Commissioner with 24
hours of the results of each test, followed by written notification
within three days.
CAPITAL PROJECT NUMBER PO79201K 02081-39
100: CONTRACT DOCUMENTS REV. May 3,2000
- 39 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631288
NYC-WTC_000416800
OCR can misread numbers and units. Confirm readings against the page image before using them.