NYC 9/11 Public Portal Document
Asbestos Abatement
be provided by Contractor at Contractor's expense.
P. Respiratory protection maintenance and decontamination procedures shall
meet the following requirements:
1. Respiratory protection shall be inspected and decontaminated on a daily
basis in accordance with OSHA 29 CFR 1910.134 (b); and
2. High efficiency filters for negative pressure respirators shall be changed
after each shower; and
3. Respiratory protection shall be the last piece of worker protection
equipment to be removed. Workers must wear respirators in the shower
when going through decontamination procedures as stated in Section 3.03
and/or 3.04.
4. Airline respirators with high efficiency filtered disconnect shall be
disconnected in the equipment room and worn into the shower. Powered
air-purifying respirator face pieces shall be worn into the shower.
Filtered/power pack assemblies shall be decontaminated in accordance
with manufacturers recommendations; and
5. Respirators shall be stored in a dry place and in such a manner that the
face-piece and exhalation valves are not distorted; and
6. Organic solvents shall not be used for washing of respirators.
Q. Authorized visitors shall be provided with suitable respirators and
instruction on the proper use of respirators whenever entering the Work
Area. Qualitative fit test shall be done to ensure proper fit of respirator.
1.16 PROTECTIVE CLOTHING
A. Provide worker protection as required by the most stringent OSHA and/or EPA
standards applicable to the work. Provide to all workers, foremen,
superintendents, authorized visitors and inspectors, protective disposable clothing
consisting of full-body coveralls, head covers, gloves and 18-inch high boot type
covers or reusable footwear.
B. In addition to personal protective equipment for workers, the Contractor shall
make available at each worksite at least four (4) additional uniforms and required
respiratory equipment each day for personnel who are authorized to inspect the
work site. He/she shall also provide, for the duration of the work at any site
involving a decontamination unit for worksite access, a lockable storage locker
for use by the Resident Engineer. In addition to respiratory masks for workers,
CAPITAL PROJECT NUMBER PO79201K 02081-36
100: CONTRACT DOCUMENTS REV. May 3,2000
- 36 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631285