NYC 9/11 Public Portal Document
Asbestos Abatement
b. R- and P-series filters shall be used when oil aerosols or fumes
(i.e., lubricants, cutting fluids, glycerin, etc.) are present. The R-
series filters are oil resistant and the P-series filters are oil proof.
c. Follow filter manufacture recommendations.
3. If a vapor hazard exists, use an organic vapor cartridge in combination
with the high efficiency filter.
H. Historical airborne fiber level data may serve as the basis for selection of the level
of respiratory protection to be used for an abatement task. Historical data
provided by the Contractor shall be based on personal air monitoring performed
during work operations closely resembling the processes, type of material, control
methods, work practices, and environmental conditions present at the site.
Documentation of aforementioned results may be requested by the City and/or
Testing Laboratory for review. This will not relieve the Contractor in providing
personal air monitoring to determine the time-weighted average (TWA) for the
work under contract. The TWA shall be determined in accordance with 29 CFR
1926.1101.
I. At no time during actual removal operations shall half-mask air purifying
respirators be allowed unless a full 8-hour TWA and ceiling concentration have
been conducted, and reviewed by the Resident Engineer. Use of single use dust
respirators is prohibited for the above respiratory protection.
J. Workers shall be provided with personally issued and individually marked
respirators. Respirators shall not be marked with any equipment that will
alter the fit of the respirator in any way. Only waterproof identification
markers shall be used.
K. Contractor shall ensure that the workers are qualitatively or quantitatively
fit tested by an Industrial Hygienist initially and every 12 months thereafter
with the type of respirator he/she will be using.
L. Whenever the respirator design permits, workers shall perform the positive
and negative air pressure fit test each time a respirator is worn. Powered
air-purifying respirators shall be tested for adequate flow as specified by
the manufacturer.
M. No facial hairs (beards) shall be permitted to be worn when wearing
respiratory protection that requires a mask-to-face seal.
N. Contact lenses shall not be worn in conjunction with respiratory
protection on asbestos projects.
O. If a worker wears glasses, a spectacle kit to fit their respirator shall
CAPITAL PROJECT NUMBER PO79201K 02081-35
100: CONTRACT DOCUMENTS REV. May 3,2000
- 35 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631284
NYC-WTC_000416796
OCR can misread numbers and units. Confirm readings against the page image before using them.