NYC 9/11 Public Portal Document
Asbestos Abatement
1910.134 and 29 CFR 1926.1101, NIOSH Standard 42 CFR 84, or as more
stringently specified otherwise, herein.
D. Where respirators with disposable filter parts are employed, the Contractor will
provide sufficient filter parts for replacement as necessary or as required by the
applicable regulation.
E. All respiratory protection shall be OSHA/NIOSH approved. All respiratory
protection shall be provided by Contractor, and used by workers in conjunction
with the written respiratory protection program.
F. Contractor shall provide respirators selected by an Industrial Hygienist that
meet the following requirements:
Airborne Concentration of
Asbestos or Conditions of Use_______ Required Respirator_______________
Not in excess of 1 fibers per cubic Half-mask air purifying respirator,
centimeter (f/cc), ten times Permissible other than a disposable respirator,
Exposure Level (PEL)______________ equipped with high efficiency filters.
Not in excess of 5 f/cc, 50 times PEL Full facepiece air-purifying respirator
equipped with high efficiency filters.
Not in excess of 10 f/cc, 100 times Powered air purifying respirator
PEL equipped with equipped with high
efficiency filters or any supplied air
respirator operated in continuous flow
mode^___________________________
Not in excess of 100 f/cc, 1,000 times Full facepiece supplied air respirator
PEL____________________________ operate in pressure demand mode.
Greater than 100 f/cc, 1,000 times Full facepiece supplied air respirator
PEL, or unknown concentration operate in pressure demand mode,
equipped with an auxiliary positive
pressure self-contained breathing
apparatus.
G. Selection of high efficiency filters:
1. All high efficiency filters shall have a nominal efficiency rating of 100
(99.97-percent effective) when tested against 0.3-micrometer
monodisperse diethyl-hexyl phthalate (DOP) particles.
2. Choose N-, R-, or P-series filters based upon the presence or absence of
oil particles.
a. N- series filters shall only be used for non-oil solid and water
based aerosols or fumes.
CAPITAL PROJECT NUMBER PO79201K 02081-34
100: CONTRACT DOCUMENTS REV. May 3,2000
- 34 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631283
NYC-WTC_000416795
OCR can misread numbers and units. Confirm readings against the page image before using them.