Police Academy asbestos abatement specifications, DDC

Machine-extracted title · confidence 48%

Contract specs for abatement of asbestos-containing materials at Police Academy.

NYC-WTC_000416762–000416866
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Abatement

1910.134 and 29 CFR 1926.1101, NIOSH Standard 42 CFR 84, or as more stringently specified otherwise, herein.

D. Where respirators with disposable filter parts are employed, the Contractor will provide sufficient filter parts for replacement as necessary or as required by the applicable regulation.

E. All respiratory protection shall be OSHA/NIOSH approved. All respiratory protection shall be provided by Contractor, and used by workers in conjunction with the written respiratory protection program.

F. Contractor shall provide respirators selected by an Industrial Hygienist that meet the following requirements:

Airborne Concentration of Asbestos or Conditions of Use_______ Required Respirator_______________ Not in excess of 1 fibers per cubic Half-mask air purifying respirator, centimeter (f/cc), ten times Permissible other than a disposable respirator, Exposure Level (PEL)______________ equipped with high efficiency filters. Not in excess of 5 f/cc, 50 times PEL Full facepiece air-purifying respirator equipped with high efficiency filters. Not in excess of 10 f/cc, 100 times Powered air purifying respirator PEL equipped with equipped with high efficiency filters or any supplied air respirator operated in continuous flow mode^___________________________ Not in excess of 100 f/cc, 1,000 times Full facepiece supplied air respirator PEL____________________________ operate in pressure demand mode. Greater than 100 f/cc, 1,000 times Full facepiece supplied air respirator PEL, or unknown concentration operate in pressure demand mode, equipped with an auxiliary positive pressure self-contained breathing apparatus.

G. Selection of high efficiency filters:

1. All high efficiency filters shall have a nominal efficiency rating of 100 (99.97-percent effective) when tested against 0.3-micrometer monodisperse diethyl-hexyl phthalate (DOP) particles.

2. Choose N-, R-, or P-series filters based upon the presence or absence of oil particles.

a. N- series filters shall only be used for non-oil solid and water based aerosols or fumes.

CAPITAL PROJECT NUMBER PO79201K 02081-34 100: CONTRACT DOCUMENTS REV. May 3,2000 - 34 -100% CONTRACT DOCUMENTS REV. 0: DATE

CITY_21MC100_006631283

NYC-WTC_000416795

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000416795Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

Asbestos, NY DOL reference

NYC-WTC_000441450

Asbestos standards reference page from NY Department of Labor materials.

Similar indexed content