Exterior sealant/caulking abatement specs, P.S. 92M

Machine-extracted title · confidence 53%

Specifications for asbestos-containing exterior sealants and caulking materials abatement.

NYC-WTC_000454574–000454656
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SECTION 02082 NIOSH Standard 42 CFR 84, or as more stringently specified otherwise, herein.

D. Where respirators with disposable filter parts are employed, the Contractor will provide sufficient filter parts for replacement as necessary or as required by the applicable regulation.

E. All respiratory protection shall be OSHA/NIOSH approved. All respiratory protection shall be provided by Contractor, and used by workers in conjunction with the written respiratory protection program.

F. Contractor shall provide respirators selected by an Industrial Hygienist that meet the following requirements:

Airborne Concentration of Asbestos or Conditions of Use_______ Required Respirator_______________ Not in excess of 1 fibers per cubic Half-mask air purifying respirator, centimeter (f/cc), ten times Permissible other than a disposable respirator, Exposure Level (PEL)______________ egui£pedwithjTigh_efficiency_^^ Not in excess of 5 f/cc, 50 times PEL Full facepiece air-purifying respirator equipped with high efficiency filters. Not in excess of 10 f/cc, 100 times Powered air purifying respirator PEL equipped with equipped with high efficiency filters or any supplied air respirator operated in continuous flow mode.___________________________ Not in excess of 100 f/cc, 1,000 times Full facepiece supplied air respirator PEL____________________________ operate in pressure demand mode. Greater than 100 f/cc, 1,000 times Full facepiece supplied air respirator PEL, or unknown concentration operate in pressure demand mode, equipped with an auxiliary positive pressure self-contained breathing apparatus.

G. Selection of high efficiency filters:

1. All high efficiency filters shall have a nominal efficiency rating of 100 (99.97-percent effective) when tested against 0.3-micrometer monodisperse diethyl-hexyl phthalate (DOP) particles.

9 Choose N-, R-, or P-series filters based upon the presence or absence of oil particles.

a. N- series filters shall only be used for non-oil solid and water based aerosols or fumes.

b. R- and P-series filters shall be used when oil aerosols or fumes (i.e., lubricants, cutting fluids, glycerin, etc.) are present. The R-series filters are oil resistant and the P-series filters are oil proof.

c. Follow filter manufacture recommendations.

02082-36

CITY_21 MCI 00_014563809

NYC-WTC_000454609

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454609Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →