3. If a vapor hazard exists, use an organic vapor cartridge in combination with the high
efficiency filter.
H. Historical airborne fiber level data may serve as the basis for selection of the level of respiratory
protection to be used for an abatement task. Historical data provided by the Contractor shall be
based on personal air monitoring performed during work operations closely resembling the
processes, type of material, control methods, work practices, and environmental conditions
present at the site. Documentation of aforementioned results may be requested by the City and/or
Testing Laboratory for review. This will not relieve the Contractor in providing personal air
monitoring to determine the time-weighted average (TWA) for the work under contract. The
TWA shall be determined in accordance with 29 CFR 1926.1101.
I. At no time during actual removal operations shall half-mask air purifying respirators be allowed
unless a full 8-hour TWA and ceiling concentration have been conducted, and reviewed by the
Resident Engineer and Construction Manager. Use of single use dust respirators is prohibited for
the above respiratory protection.
J. Workers shall be provided with personally issued and individually marked respirators.
Respirators shall not be marked with any equipment that will alter the fit of the respirator in any
way. Only waterproof identification markers shall be used.
K. Contractor shall ensure that the workers are qualitatively or quantitatively fit tested by an
Industrial Hygienist initially and every 12 months thereafter with the type of respirator he/she
will be using.
L. Whenever the respirator design permits, workers shall perform the positive and negative air
pressure fit test each time a respirator is worn. Powered air-purifying respirators shall be tested
for adequate flow as specified by the manufacturer.
M. No facial hairs (beards) shall be permitted to be worn when wearing respiratory protection that
requires a mask-to-face seal.
N. Contact lenses shall not be worn in conjunction with respiratory protection on asbestos projects.
O. Tf a worker wears glasses, a spectacle kit to fit their respirator shall be provided by Contractor at
Contractor's expense.
P. Respiratory protection maintenance and decontamination procedures shall meet he following
requirements:
1. Respiratory protection shall be inspected and decontaminated on a daily basis in
accordance with OSHA 29 CFR 1910.134 (b); and
2. High efficiency filters for negative pressure respirators shall be changed after each
shower; and
3. Respiratory protection shall be the last piece of worker protection equipment to be
02082-37