NYC 9/11 Public Portal Document
§1-94 TITLE 15—DEPT. OF ENVIRONMENTAL PROTECTION
(h) The recontainerized items of ACM and cleaned, bagged equipment
shall be placed in open top, watertight plastic carts. These carts shall be held
in the holding area pending removal. The carts shall be HEPA-vacuumed or
wet-cleaned following the removal of the containers of ACM from them.
(i) The exit from the waste decontamination enclosure system shall be
secured to prevent unauthorized entry.
(j) The carts shall be stored in a holding area of the work site.
§1-94 Maintenance of Decontamination Enclosure Systems and Barri
ers. The following procedures shall be followed during the conduct of abate
ment activities on large asbestos projects:
(a) All plastic barriers inside the work place and partitions constructed to
isolate the work area from occupied areas shall be inspected by the asbestos
handler supervisor at least twice per shift.
(b) Smoke tubes shall be used to test the integrity of the work area barriers
and the decontamination enclosure systems daily at a minimum both before
abatement activity begins and at the end of each shift. A visual inspection of
idle barriers, including the use of differential manometers, shall be considered
acceptable as a back-up test.
(c) Damage and defects in the decontamination enclosure system shall be
repaired immediately.
(d) At any time during the abatement activity, if visible emissions are
observed, or elevated asbestos fiber counts outside the work area are meas
ured, or if damage occurs to barriers, abatement shall stop. The source of the
contamination shall be located, the integrity of the barriers shall be restored,
and visible residue shall be cleaned up using appropriate HEPA vacuuming
and wet cleaning procedures immediately.
(e) Inspections, observations, and unusual incidents (e.g. barrier damage,
contamination beyond the work area, etc.) shall be documented in the log by
the asbestos handler supervisor.
5850 RCNY 5-31-98
. ^T-.. CITY_21MC1OO_OO6242991
NYC-WTC_000411860
OCR can misread numbers and units. Confirm readings against the page image before using them.