NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

Air quality sampling report, Pace Plaza, Sept 2001

Machine-extracted title · confidence 52%

Pace University air sampling report addressing asbestos concerns and testing in Pace Plaza.

NYC-WTC_000366571–000366575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

B. Link CPN: 01204 Asbestos Sampling Report 09/18/01

Introduction

Golden Corporation was retained by Pace University to conduct asbestos testing at Pace Plaza, 41 Park Row, 156 William Street and 135 William Street in response to the incident at the World Trade Center.

On September 15, and September 17, 2001, Colden collected air samples from representative areas within Pace Plaza, 41 Park Row, 156 William Street and 135 William Street. Additionally, air samples were collected outdoors at Pace Plaza and 156 William Street. Air samples collected in Pace Plaza and 41 Park Row were collected while the air handlers were operating. All air samples were analyzed using Transmission Electron Microscopy in accordance with the EPA AHERA method.

Bulk dust samples were collected fi-om representative Pace Plaza dorm rooms that were subject to large quantities of outside dust following the WTC incident. Dust samples were also collected from office areas in 156 Williams Street. Dust samples were analyzed in accordance with the EPA method using Polarized Light Microscopy.

Results and Discussion

All air sample results were within safe limits established by the Environmental Protection Agency (EPA), the New York State Department of Labor (NYS DOL) and the New York City Department of Environmental Protection (NYC DEP), A summary of the air sample data is presented below in Tables 1.0, 2.0, 3.0 and 4.0.

Results of the bulk dust samples were all less than 1% asbestos. Materials containing less than 1% asbestos do not meet the EPA’s definition of asbestos containing materials and therefore the dust is considered non-hazardous and EPA, NYS DOL and NYC DEP regulations governing asbestos containing materials do not apply.

The bulk dust sample results are presented below in Table 5.0 and 6.0.

All air and bulk samples were analyzed by Scientific Laboratory of NY, NY. Scientific Laboratory is an American Industrial Hygiene Association (AIHA) accredited laboratory.

Page 2 of 5

CITY_21MC100_002849901

NYC-WTC_000366572

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000366572Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000366583

Golden’s air sampling report for Pace Plaza showing results tables.

Similar indexed content

NYC-WTC_000366591

Chain-of-custody and sampling report for Pace Plaza asbestos air monitoring.

Similar indexed content

Compare copies and versions →